8
Debugging
Echo: Off
Debugging information that is sent to the software (irrelevant for normal operation)
Info: Off
Debugging information that is sent to the software (irrelevant for normal operation)
Errors: Off
Debugging information that is sent to the software (irrelevant for normal operation)
Dry run: Off
Debugging information that is sent to the software (irrelevant for normal operation)
Configuration
General
Baud rate:250000
Setting of the transfer speed from the computer
Stepper Inactive
Time setting until the motors are switched off in standby
Max. Inactive
Time setting until the display is switched off in standby
Acceleration
Print X: 1000
Setting of the printing acceleration of the X-axis
Print Y: 1000
Setting of the printing acceleration of the Y-axis
Print Z: 1000
Setting of the printing acceleration of the Z-axis
Move X:1000
Setting of the travel speed of the X-axis
Move Y:1000
Setting of the travel speed of the Y-axis
Move Z:1000
Setting of the travel speed of the Z-axis
Jerk :10.0
Acceleration of X and Y axis at small steps
Z-Jerk : 20.0
Acceleration of Z-axis in small steps
Feed rate
Max X: 500
Max. speed of the X-axis
Max Y: 500
Max. speed of the Y-axis
Max Z: 50
Max. speed of the Z-axis
Home X: 200
Max. speed of the X-axis when moving to the home position
Home Y: 200
Max. speed of the Y-axis when moving to the home position
Home Z: 20
Max. speed of the Z-axis when moving to the home position
Extruder
Steps/mm 71.0
Basic setting extruder /
ATTENTION: do not adjust
Start FR: 18
Basic setting extruder /
ATTENTION: do not adjust
Max FR 25
Basic setting extruder /
ATTENTION: do not adjust
Accel:6000
Basic setting extruder /
ATTENTION: do not adjust
Stab. Time: 20
Basic setting extruder /
ATTENTION: do not adjust
Wait Units: 0 mm
Basic setting extruder /
ATTENTION: do not adjust
Wait Temp. 150°C
Basic setting extruder /
ATTENTION: do not adjust
Advance lin: 0
Basic setting extruder /
ATTENTION: do not adjust
Advance quad: 0
Basic setting extruder /
ATTENTION: do not adjust
Control:PID
Basic setting extruder /
ATTENTION: do not adjust
DT/PID P: 37.52
Basic setting extruder /
ATTENTION: do not adjust
PID I: 10.00
Basic setting extruder /
ATTENTION: do not adjust
PID D: 35.18
Basic setting extruder /
ATTENTION: do not adjust
Drive Min: 60
Basic setting extruder /
ATTENTION: do not adjust
Drive Max: 130
Basic setting extruder /
ATTENTION: do not adjust
PID Max: 255
Basic setting extruder /
ATTENTION: do not adjust
Z Calib
Home All
Move all axes into the home position
Z Position
Move Z-axis into a settable position / display of the limit switch condition
Heat Bed Scan
Heating bed calibration