Connection of the device lines
Connect the device lines to the main PCB as follows:
Line
Terminal main PCB
Connected components
8
X15
Limit switch Z-direction
9
X26
LED lighting right
10
X27
LED lighting left
11
X13
Limit switch X direction
12
X9
Thermal sensor heating plate
13
X14
Limit switch Y-direction
14
X5
Thermal sensor extruder
15
X7
Elongation measuring strip
16
X16
Motor Z-direction
17
X11
Motor X-direction
18
X12
Motor Y-direction
19 (4-pin)
X17
Motor extruder
19 (2-pin red/blue)
X24
Fan
19 (2-pin pink/grey)
X4
Heating extruder
20
X29 + protective ground at middle screw operating unit cover
Heating plate
The ring eyelet of the protective ground at line 0 is attached with sprockets and an additional nut at the middle attach-
ment screw of the operating unit cover.
Caution: This connection creates the safety-technically important contact between the housing parts and the protec-
tive ground. Always observe the position of the washers and sprockets:
Housing > sprocket > ring eyelet > sprocket > washer > nut M (see image section)
Route the lines cleanly with small cable ties (99 mm) and a self-adhesive cable tie holder and secure them.