System installation 2-3
Installing the SP2-1 scanning probe to your
machine tool
Assembling the clutch assembly to the SP2-1 probe
Note...
The adapter assembly [1] is only required in instances where the probe
is to be mounted to a shank incorporating a 20mm collett chuck.
Assemble the clutch assembly [4] and, where required, the adapter
assembly [1] to your SP2-1 scanning probe [6] as follows (see Figure 2.1):
1.
Remove the SP2-1 probe [6], the clutch assembly [4], and, where
required, the adapter assembly [1] from the carrying case.
2.
Remove the SP2-1 probe [6] from its packaging.
Note...
In some instances, the anodised ring [3] may be attached to the SP2-1
probe. If this is the case, remove the anodised ring from the probe by
releasing the three M4 capscrews [2].
3.
Remove the clutch assembly components from their packaging and, if
applicable, remove any elastic bands or adhesive tape securing the
anodised ring [3].
4.
Remove the adapter assembly [1] from its packaging (if applicable).
Continued on Page 2-4