3-5
www.renishaw.com/nci-6
Wiring
Connecting to the NC unit
* If the laser beam is to be switched on and off
independently of the receiver, do not connect
this red wire to pin 8 . Connect the transmitter
as shown on page 3-7 .
† Do not connect screen connections if
the NC unit housing is connected to the
machine ground reference (i.e. R ≤ 1Ω).
NC unit
Digital
voltmeter
(used only
during NC
unit set-up)
NCi-6 connector CN1
Set-up DVM
Set-up DVM
Auxiliary 11 Vdc to 30 Vdc
Analogue output 1
Set-up
Analogue output 2
0 Vdc
13 Vdc to 14 Vdc
Screen
Probe status
Rx
Tx
White
Purple
Blue
Black
Red
Screen †
Grey
Black
Red *
Screen †
Grey
1
2
3
4
5
6
7
8
9
10
Содержание NCi-6
Страница 1: ...renishaw NCi 6 non contact tool setting interface www renishaw com nci 6 Installation guide...
Страница 8: ...1 4 NCi 6 non contact tool setting interface Before you begin This page is intentionally left blank...
Страница 11: ...2 3 www renishaw com nci 6 NCi 6 top label NCi 6 bottom label...
Страница 18: ...2 10 NCi 6 non contact tool setting interface NCi 6 basics This page is intentionally left blank...
Страница 28: ...3 10 NCi 6 non contact tool setting interface System installation This page is intentionally left blank...
Страница 30: ...4 2 NCi 6 non contact tool setting interface Maintenance This page is intentionally left blank...