![Renishaw NCi-6 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/renishaw/nci-6/nci-6_installation-manual_1441458016.webp)
2-8
NCi-6 non-contact tool setting interface: NCi-6 basics
IMPORTANT: Setting a switch
When setting a switch to either the On or Off position, apply firm pressure to make sure it is fully in position.
Switch bank SW1
Switch
On
Off
1
Not used
On
Off
Not used .
2
NC set-up
On
Off
Used when setting up an NC unit . Set this switch to On so that the
alignment voltage can be maximised . After maximising the voltage,
set the switch to Off so that the automatic gain circuitry can set the
operating voltage .
3
Drip rejection On
Off
When the drip rejection mode is set to On, the effects of individual
drops of coolant on measurements are filtered out.
NOTE:
For safe operation, set the spindle speed and spindle
override as described below .
4
Spindle r/min 500
1000
Used with drip rejection . For safe operation, the spindle speed must
be fixed at a whole multiple, e.g. 1000, 2000, or 3000; or 500, 1000,
or 1500, and the spindle override must be disabled .
Switch bank SW2
CAUTIONS:
With the SSR output switch(es) set to Off, i .e . normally open (N .O .), the respective output will remain in a
non-triggered state if the power supply is interrupted and/or a poor connection is made to the SSR .
If using SSR2 as an oscillating or pulsed output for a trigger signal to the control, the level output SSR1
must be used to guarantee a reliable probe status check .
Switch
On
Off
1
SSR1
N .C .
N .O .
Sets the SSR output to either normally closed (N .C .) or normally
open (N .O .) .
2
SSR2
N .C .
N .O .
As above .
3
SSR2
Type1
Level
Pulsed Sets the SSR2 output to level or pulsed .
Refer to page 2-9 .
4
Pulse width
20 ms 100 ms Sets the pulse width to either 20 ms or 100 ms (For more
) .
M-code 3 may be used to invert the switch setting .
NOTE:
For the cycle to work, the pulse width value selected must
be the same as the value that is configured in the tool setting
software .
Содержание NCi-6
Страница 1: ...renishaw NCi 6 non contact tool setting interface www renishaw com nci 6 Installation guide...
Страница 8: ...1 4 NCi 6 non contact tool setting interface Before you begin This page is intentionally left blank...
Страница 11: ...2 3 www renishaw com nci 6 NCi 6 top label NCi 6 bottom label...
Страница 18: ...2 10 NCi 6 non contact tool setting interface NCi 6 basics This page is intentionally left blank...
Страница 28: ...3 10 NCi 6 non contact tool setting interface System installation This page is intentionally left blank...
Страница 30: ...4 2 NCi 6 non contact tool setting interface Maintenance This page is intentionally left blank...