![Renishaw NCi-6 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/renishaw/nci-6/nci-6_installation-manual_1441458014.webp)
2-6
NCi-6 non-contact tool setting interface: NCi-6 basics
Interface LEDs – status LED
LED colour
Tool set mode 1
Tool set mode 2
Green/amber Flashing at 1 Hz .
The system operating voltage is too
high .
The system will continue to function,
but for optimum performance repeat
the set-up and alignment procedures .
The probe is untriggered .
Flashing at 1 Hz .
The system operating voltage is too high .
The system will continue to function, but for
optimum performance repeat the set-up and
alignment procedures .
The probe is triggered .
Green
The beam is clear .
The probe is untriggered .
The beam is clear .
The probe is triggered .
Amber
The beam is partially blocked . *
The probe is untriggered .
The beam is partially blocked . *
The probe is triggered .
Red
The beam is blocked .
The probe is triggered .
The beam is blocked .
The probe is untriggered .
No light
No power to the unit
* If the laser beam is clear and the LED is amber, this indicates that the system will continue to function,
but for optimum performance maintenance is required .
Refer to the applicable
installation and user’s guide
(for
NC4
, Renishaw part number H-2000-5230 or
NC4+
, Renishaw part number H-6270-8501 or
NC4+ Blue
, Renishaw part number H-6435-8501), for
details of the possible actions required .
LED colour
High speed broken tool
detection mode
Latch mode
Green/amber Not applicable .
Flashing at 1 Hz .
The output is not latched .
The system operating voltage is too high .
The system will continue to function, but for optimum
performance repeat the set-up and alignment procedures .
Green
Not applicable .
The beam is clear .
The output is not latched .
Amber
The output is not latched .
The beam is blocked .
The output is not latched .
The beam is blocked . *
Red
The output is latched .
The tool is broken .
The output is latched .
No light
* If the laser beam is clear and the LED is amber, this indicates that the system will continue to function,
but for optimum performance maintenance is required .
Refer to the applicable
installation and user’s guide
(for
NC4
, Renishaw part number H-2000-5230 or
Swi
NC4+
, Renishaw part number H-6270-8501 or
NC4+ Blue
, Renishaw part number H-6435-8501), for
details of the possible actions required .
Содержание NCi-6
Страница 1: ...renishaw NCi 6 non contact tool setting interface www renishaw com nci 6 Installation guide...
Страница 8: ...1 4 NCi 6 non contact tool setting interface Before you begin This page is intentionally left blank...
Страница 11: ...2 3 www renishaw com nci 6 NCi 6 top label NCi 6 bottom label...
Страница 18: ...2 10 NCi 6 non contact tool setting interface NCi 6 basics This page is intentionally left blank...
Страница 28: ...3 10 NCi 6 non contact tool setting interface System installation This page is intentionally left blank...
Страница 30: ...4 2 NCi 6 non contact tool setting interface Maintenance This page is intentionally left blank...