15.4 Siemens DRIVE-CLiQ serial communications
Siemens DRIVE-CLiQ specifications
Power supply
24 V 1.8 W maximum (75 mA @ 24 V), 24 V as per DRIVE-CLiQ
specification. 24 V power is provided by the DRIVE‑CLiQ network
Maximum total
cable length
Readhead to DRIVE-CLiQ interface 9 m
(Refer to Siemens DRIVE‑CLiQ specifications for maximum cable
length from interface to controller)
Extension cables from the FORTiS-S FS
DRIVE-CLiQ interface to
controller should be sourced directly from Siemens
Connector
tightening torque
M12 – 4 Nm
Vibration
(interface)
< 100 m/s² to IEC 60068-2-6
Environment protection
(interface)
IP67
M12
Ø
15
50
M12 × 1.0*
Siemens DRIVE-CLiQ signals between readhead and interface
Function
Signal
Wire colour
Pin-out
M12
Power
5 V
Brown
2
0 V
White
5, 8
Serial
communications
A+
Violet
3
A−
Yellow
4
Reserved
Do not connect
Grey
7
Pink
6
Shield
Shield
Cable braid
Case
* The recommended tightening torque is 4 Nm.
NOTE:
On Siemens DRIVE-CLiQ systems the connector between the readhead cable and extension
cable will mate via the A-9796-0575 interface.
IM PORTANT:
The shield should be connected to the machine Earth (Field Ground).
IMPORTANT:
If the flying lead variant is used or the connector is modified or replaced, the customer must
ensure that both 0 V cores (White and Green) are connected to 0 V. In such situations, care should also
be taken to ensure that 0 V and Earth remain properly insulated from each other throughout the cable run.
*
See
for details.
FORTiS-S FS grounding and shielding – Siemens DRIVE-CLiQ versions
Customer
electronics
Extension cable
(supplied by
Siemens)
Encoder
A-9796-0575
interface
*
Readhead
cable