28
Original instructions
Siemens DRIVE-CLiQ interface installation drawing
Single readhead (A-9796-0575)
M12 8-way male for
DRIVE-CLiQ connection
(including power supply)
M12 8-way female for
readhead connection
2 mounting holes Ø5.5 through
Screw grade: ISO 4762-M5
Torque: 4 Nm
Recommended thread engagement: ≥ 5 mm
82
7
31 26
43
20
96
14.6
19.25
12.3
57.5
10
Dimensions in mm
15.4.1 Siemens DRIVE-CLiQ interface
RDY LED functions
Colour
Status
Description
-
Off
Power supply is missing or outside permissible tolerance range
Green
Continuous light
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place
Orange
Continuous light
DRIVE-CLiQ communication is being established
Red
Continuous light
At least one fault is present in this component
NOTE:
The LED is activated regardless of whether the
corresponding messages have been reconfigured
Green/Orange
or
Red/Orange
Flashing light
Component recognition via LED is activated (p0144)
NOTE:
Both options depend on the LED status when component
recognition is activated via p0144=1
Function
Signal
Pin-out
M12
Power
24 V
1
0 V
5
DRIVE-CLiQ
communications
RX+
3
RX−
4
TX+
7
TX−
6
Shield
Shield
Case
Status LED function
STATUS displays the readhead set-up status as shown on the readhead set-up LED; see
for more details.
Siemens DRIVE-CLiQ interface output
6