vii
Before you begin
(continued)
47 CFR Section 15.105
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used
in accordance with this installation guide, may cause
harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause
harmful interference, in which case you will be required to
correct the interference at your own expense.
Safety
Information to the user
In all applications involving the use of machine tools or
CMMs, eye protection is recommended.
Information for the machine supplier
It is the machine supplier’s responsibility to ensure that
the user is made aware of any hazards involved during
operation, including those mentioned in Renishaw
product literature, and to ensure that adequate guards
and safety interlocks are provided.
Under certain circumstances, the probe signal may
falsely indicate probe seated condition. Do not rely on
probe signals to halt the movement of the machine.
The automatic probe cover (APCA-45) system must
be installed by a competent person, observing relevant
safety precautions. Before starting work, ensure that
the machine tool is in a safe condition with the power
switched OFF and the power supply to the HSI or HSI-C
disconnected.
Warnings
The following residual risks of this device need to be
managed to an acceptable level by the integrator:
•
Noise levels: this device emits noise as an essential
part of its operation and has been measured at
76 dB.
•
Pinch point: when this device operates there is a
pinching hazard between the stylus cube and the
cover
•
Care must be taken when installing or cleaning the
product inside the machine tool to ensure sharp
objects are avoided.
•
Ejection of debris: when air bleed is activated debris
(including metal particles) can be ejected from the
cover
Содержание APCA-45
Страница 1: ...Installation and user s guide H 6596 8500 01 B APCA 45 tool setting probe...
Страница 2: ......
Страница 4: ...This page is intentionally left blank...
Страница 27: ...9 Preparing the machine for APCA 45 installation continued Acceptable orientation of the APCA 45 Recommended...
Страница 33: ...15 Pneumatic options continued Bulkhead Dual Air air bleed circuit 1 V3 V2 V1...
Страница 35: ...17 Pneumatic options continued Dual Air air bleed circuit 2 Bulkhead V3 V2 V1...
Страница 47: ......