![Renishaw APCA-45 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/renishaw/apca-45/apca-45_installation-and-user-manual_1441447029.webp)
11
Connecting the APCA-45 to an HSI-C interface and the CNC
Standard probe connector (3-way)
17 Screen
16 Probe Input +
15 Probe Input –
CNC
Retract confirm input
Supply 12 V – 30 V
Supply 0 V
Screen
Controller
protective earth
Controller reference ground
HSI-C interface
Machine tool
Block 1
2
4
1
5
3
1 Supply 12 V – 30 V
2 Supply 0 V
3 Supply 0 V
4 Screen
22 Probe status NC
23 Probe status common
24 Probe status NO
26 External LED 0 V
25 External LED 10 V
Block 4
Block 5
Block 6
APCA-45
Block 3
9 12 V – 30 V out
(fused 100 mA)
10 Inhibit input
11 Inhibit return
12 0 V
NOTES:
When the APCA-45 is not being
used, it is recommended that
the inhibit function is used.
The retract confirm output
could be used to set the inhibit
function (for more information
see “Probe inhibit function” on
page 12).
When connecting the APCA-45
to the HSI-C interface, please
use the connection labelled
STANDARD PROBE.
Connect either pin 22 or pin 24,
but do not connect both wires.
Pin
APCA-45 connections
2
Retract confirm sensor
4
Probe input +
1
Probe input –
5
Supply 0 V
3
Supply 12 V – 30 V
Probe
input
Status
Normally
open
(NO)
Normally
closed
(NC)
Probe
triggered
Closed
Open
Probe
seated
Open
Closed
Содержание APCA-45
Страница 1: ...Installation and user s guide H 6596 8500 01 B APCA 45 tool setting probe...
Страница 2: ......
Страница 4: ...This page is intentionally left blank...
Страница 27: ...9 Preparing the machine for APCA 45 installation continued Acceptable orientation of the APCA 45 Recommended...
Страница 33: ...15 Pneumatic options continued Bulkhead Dual Air air bleed circuit 1 V3 V2 V1...
Страница 35: ...17 Pneumatic options continued Dual Air air bleed circuit 2 Bulkhead V3 V2 V1...
Страница 47: ......