- 19 -
8. Technical Data
Working Voltage
230 V
120 V
Permissible mains voltage:
220 - 240 V
120 V
Mains frequency:
50 / 60 Hz
60 Hz
Suction turbine power: *)
1400 W
1400 W
max. connecting power: *)
2000 W
360 W
Total connected power: *)
3400 W
1800 W
Mains input fuse:
2 x 15 A (T)
max. connection pressure:
8 bar
[116 psi]
min. connection pressure:
4.5 bar
[65 psi]
LpA **) (at max. volume flow):
56,9 dB(A)
Number of suction hoses:
2
Volume flow, max. per suction hose:
3300 l/min
Vacuum pressure, max.:
200 hPa
[2.9 psi]
Fine particle filter:
Filter surface area, approx.:
0.8 m²
[1240 sq inch]
FIlterquality:
Class M according to EN60335-2-69
Fill volume, dust bag, approx.:
7.5 l
[2 US gal]
Dimensions (Width x Height x Depth):
224 x 591 x 584 mm
[8.8 x 23.3 x 23.0 inch]
Weight (empty), approx.:
27 kg
[59.5 lbs]
Ø Suction fittings:
internal:
external:
45 mm [1.77 inch]
50 mm [1.97 inch]
*) Working voltage power
**) Sound pressure levels according to EN ISO 11202
EN