R0E521000CPE00 User’s Manual
2. Setup
REJ10J0845-0600 Rev.6.00 Aug. 20, 2009
Page 35 of 92
2.8 Self-check
2.8.1 Self-check Procedure
Self-check is used to verify the emulator function works properly. To run the self-check of the emulator, do so as explained
here below. While the self-check is in progress, the LEDs will change as shown in Figure 2.18.
(1) If the user system is connected, disconnect it.
(2) Set the jumpers as the factory-settings to execute the self-check (see Table 2.6).
(3) Within 2 seconds of activating power to the emulator, press the system reset switch on the emulator upper panel.
(4) Check the SAFE LED starts flashing and then press the system reset switch again.
(5) The self-check will start. If the normal result is displayed in about 20 seconds, the self-check terminated normally.
Table 2.6 Jumper settings for the self-check
Jumper Setting
MCU power supply source selection jumper (JP1)
INT
MCU power supply voltage selection jumper (JP2)
5V
POWER jumper
INT
RESET pin pullup jumper
UP
Figure 2.18 Self-check procedure
POWER
CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
RESET
(1 ) Within 2 seconds of activating power ,
press the reset switch .
(2 ) Check that the SAFE LED starts
blinking, then press the system reset
switch again.
( 3 ) Target status LEDs start blinking at random intervals
.
Normal
RESET
ON
OFF
Blinking
It takes 20 seconds at XIN =20 MHz.
LED1
LED2
POWER
SAFE
POWER
CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
LED1
LED2
POWER
SAFE
POWER
CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
LED1
LED2
POWER
SAFE
POWER
CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
LED1
LED2
POWER
SAFE
LED1
LED2
POWER
SAFE
Error
POWER
CLOCK
RESET
RUN
LED3
LED4
LED5
LED6
Self- check starts.
SAFE LED status
ON
OFF
Blinking
SAFE LED is turned off and one or more target status
LEDs start blinking according to the error type .
LED display