QB-V850MINIL, QB-V850MINI Emulator 4. Debugging with In-Circuit method
R20UT0221EJ0400 Rev.4.00
Page 67 of 86
2013.08.30
(
3
)
Power application to target system
Apply the power to the target system. After power application, confirm that the TARGET LED on
QB-V850MINIL or QB-V850MINI is lit.
(
4
)
Running the software
Start up and run the software as described in the supplied user's manual.
4.3.7
System shutdown
Terminate debugging and shutdown the system in the following order.
(1) Terminate the software.
(2) Turn off the power to the target system.
(3) Disconnect the USB cable from the host machine.
Caution
If the above order is not observed, QB-V850MINIL or QB-V850MINI or the self-check board may be
damaged.
4.4
Default Settings (V850MINI Self-check board)
Table 4-3. Default Settings of Self-Check Board
Item
Setting
Description
OSC1
An 8 MHz resonator is mounted at shipment.
There is no need to change the setting when using an 8 MHz resonator as is.
When changing the setting, refer to
4.3.3 Clock settings
for details.
OSC2
A 32.768 kHz resonator is mounted at shipment.
Do not change the frequency.
SW1
SW1 is set to “Self Check” by default.
Refer to
4.3.4 Switch settings
for how to set the switches.
Adapter
Self Check