3.4 Mounting A-D Conversion Bypass Capacitors
There is a foot pattern on the M306K9T-EPBM board for mounting bypass capacitors for the A-D
conversion circuit near the MCU. Mount suitable bypass capacitors as occasion demands. Figure 3.6
shows where they are installed and the configuration of this product.
Figure 3.6 Foot pattern for A-D conversion bypass capacitors
IMPORTANT
Note on the A-D Converter Function:
• Because a converter board and other devices are used between the evaluation MCU
and the target system, the A-D converter operates differently from that of an actual
MCU. Make the final evaluation of the A-D converter with an actual MCU.
C1: V
REF
-AV
SS
bypass capacitor
C2: AV
CC
-AV
SS
bypass capacitor
M306K9T-EPBM
MADE IN JAPAN
C1
C2
C1
C2
P87
XCIN
P86
OPEN
OPEN
XOUT
SW2
SW1
SW3
V
REF
AV
CC
AV
SS
REV.A
AV
SS