background image

 

 

Setup and Operations 

 
Before using the ZRC-90, please install the batteries:

 

 

2xAAA (alkaline is recommended) batteries are required for 
operation.  

 

Remove the battery cover on the back of your remote. 

 

Check the polarity of the batteries and the "+/-" marks inside the 
battery compartment. 

 

Insert the batteries.

 

 

 

Push the battery cover back in place. 

 

L

 CAUTION (battery safety)

 

Use new batteries of the recommended type and size only. 

 

Never mix used and new batteries together. 

 

To avoid chemical leaks, remove batteries from the remote 
controller if you do not intend to use the remote for an 
extended period of time. 

 

Dispose of used batteries properly; do not burn or bury them.

 

(Please carefully read through the following sections of this user 
manual and store for future reference.) 

 

 

ZRC-90 can be included and operated in any Z-Wave network with 
other Z-Wave certified devices from other manufacturers and/or 
other applications. All non-battery operated devices within the 
network will act as repeaters regardless of vendor to increase 
reliability of the network. 

 

ZRC-90 can act as a 

secondary Central Scene Controller 

and trigger 

the pre-defined scenes through the gateway. Please follow “Add ZRC-
90 into gateway network” by the procedures of “Learn mode” and 
“Scene activation and deactivation”. 
 
 

Z-Wave Learn mode 

 

ZRC-90 can also receive network information from other controllers 
by enter “Learn mode”. 
 
(Add / Remove ZRC-90 into / from gateway network) 

 

Step 

Setup Key 

Setup LED Indication 

on ZRC-90 

Refer to your primary controller
instructions to process the Inclusion
/ Exclusion setup procedure. 

Содержание Scene Master

Страница 1: ...1 ZRC 90 Scene Master Operating Instructions Master your home Master your life ...

Страница 2: ... a home control App The Scene Master is ideal for kids elderlies and guests who may not have full access to your smart home s mobile application and hence may not have the rights to switch on various lighting heating air conditioning and other home appliance With a convenient snap in wall mount the ZRC 90 can also be removed to keep it handy while you go about your home for the ultimate in simple ...

Страница 3: ...imary and secondary controllers operating on the same system A Z Wave network has its own unique ID code so that controllers not in the network cannot control the system Scene A collection of Z Wave devices configured to turn to a specific level setting mode or perform an operation Scenes are usually activated by a controller timed event or specific conditions Primary Controller The first controll...

Страница 4: ...network To avoid inconsistency all node ID allocations are maintained by the SIS Inclusion Controller The SIS enables other controllers to include exclude nodes to from the network When SIS functionality is enabled the controller also takes the role as the Primary Controller because it has both latest network topology and allocated node IDs All the other controllers are called Inclusion Controller...

Страница 5: ...d control keys of ZRC 90 LED indication for Operation and Setup Wall mount bracket Scene control keyboard Setup buttons Upgrade header Upgrade slide switch Battery door Back block for plastic insert LED indication for Operation and Setup ...

Страница 6: ...D light up Create Primary Press the keys until LED light up Create Secondary Press the keys until LED light up Reset to factory default Press and keep holding 10 seconds then triple click Slide switch OP Normal operation default PC PC firmware upgrade mode The slide switch is designed for firmware upgrade by supplier please switch to OP direction for normal operation ...

Страница 7: ...hrough the following sections of this user manual and store for future reference ZRC 90 can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated devices within the network will act as repeaters regardless of vendor to increase reliability of the network ZRC 90 can act as a secondary Central Sc...

Страница 8: ...f if the command or operation is invalid Notes 1 If the device already existed into the network the unit will exit Learn mode automatically after 5 seconds 2 If the device does not exist into the network and no command from gateway the unit will exit Learn mode automatically after 30 seconds Scene activation and deactivation The real actions of scene will be depended on each gateway interpretation...

Страница 9: ...istening mode by click once on W button LED will keep flashes slowly 2 Listening mode will exit automatically after 30 seconds of inactivity LED stay off Notes 1 The mode must not be exited during communication process with another controller Please wait for entire communication process to be completed 2 It is not allowed to enter any user input from the remote s hard key after entry this mode ZRC...

Страница 10: ...etwork 3 In a Z Wave network only the primary controller or inclusion controller can add or include devices into its network If ZRC 90 is configured as a secondary controller it will report Error if users attempt to use ZRC 90 to add a device into its network 4 If no ACK signal received for more than 30 seconds the Add Device mode will exit automatically Removing Device from the Network Step Setup...

Страница 11: ...ller and ZRC 90 will act as a secondary controller This primary shift is done by following the steps below Step Setup Key Setup LED Indication on ZRC 90 1 Place the two controllers close to each other 2 Press W L buttons simultaneously until LED light up LED will keep flashes slowly 3 Please make sure the target primary controller is setup to receive information mode e g target primary controller ...

Страница 12: ...he Learn mode if this is a another ZRC 90 Please refer to the target controller user manual for more information Target secondary controller will act as a secondary controller after this action Original ZRC 90 primary controller will still keep in a primary controller after this action LED will flashes slowly until complete the step of Create a Secondary Controller Reset to factory default ZRC 90 ...

Страница 13: ...r electrical shock Do not mount to locations subject to high temperatures high humidity or exposure to water Doing so could cause a fire or electrical shock Do not mount to locations subject to large amounts of vibration large jolts or large forces These could cause an injury if the unit falls and breaks MOUNTING PROCEDURE PRECAUTIONS Do not modify parts or use the unit in ways other than its inte...

Страница 14: ...tenna direction 2 Before mounting to a wall be sure to fully read the precautions Mount to the wall bracket Dismount from wall bracket Figure 3 Installation Technical Specifications Model no BW8510US ZRC 90US BW8510EU ZRC 90EU BW8510AU ZRC 90AU BW8510RU ZRC 90RU BW8510IN ZRC 90IN BW8510IL ZRC 90IL BW8510JP ZRC 90JP RF frequency 908 42MHz ZRC 90US 868 42MHz ZRC 90EU 921 42MHz ZRC 90AU 869 02MHz ZRC...

Страница 15: ...m x 13 5mm Weight 60g main unit and batteries excluded 15g wall mount bracket Checking Accessories After opening the cover of the packing box check that the following accessories are included ZRC 90 Scene Master Plastic insert Wall mount bracket Wall anchor x 2pcs Screw x 2pcs User Manual Warranty sheet Scene label sheet Scene Reference List Scene Button Action in single click Action in double cli...

Страница 16: ...es tend to leak 3 Do not use corrosive or abrasive cleansers on your unit 4 Keep the unit dust free by wiping it with a soft dry cloth 5 Do not disassemble the unit it contains no user serviceable parts FCC Notice This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any...

Страница 17: ...d the user authority to operate the equipment Warnings Do not modify the unit in any way Risk of fire Risk of electrical shock Risk of burns Do not dispose of electrical appliances and unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available There is no user serviceable parts in this unit Use only power sup...