Key Features 

-

 

Controls up to 8x2 pre-set scenes and 8 groups dimming function 

-

 

One learn-key setup and simple operation  

-

 

Report for key pressed 1 time, 2 times, released and held down 

-

 

Unlimited controlling capability through gateway 

-

 

Able to act as a primary or secondary controller  

-

 

Z-Wave Plus compliant  

-

 

Super thin, elegant design and able to mount to the wall-bracket 

 
 

Glossary 

 

Device or Node

 

Devices and nodes are all terms to describe 
an individual Z

­

Wave device. These are all 

interchangeable when setting up your Z-
Wave network. 

Inclusion

 

Add a Z-Wave device to the network.  

Exclusion

 

Remove a Z-Wave device from the network. 

Z-Wave 
Network 

 

A collection of Z-Wave devices controlled by 
primary and secondary controllers operating 
on the same system. A Z-Wave network has 
its own unique ID code so that controllers 
not in the network cannot control the 
system.  

Scene

 

A collection of Z-Wave devices configured to 
turn to a specific level, setting, mode, or 
perform an operation. Scenes are usually 
activated by a controller, timed event, or 
specific conditions.  

Primary 
Controller 

The first controller used to set up your 
devices and network. Only the Primary 
Controller can be used to include or remove 
modules from a network. It is recommended 
that you mark the primary controller for 
each network for ease in modifying your 
network.  

Secondary 
Controller

 

A controller containing network information 
about other modules within the network 
and is used for controlling devices. 
Secondary controller is created from the 
Primary Controller and cannot include or 
remove modules to the network.  

Содержание Scene Master

Страница 1: ...1 ZRC 90 Scene Master Operating Instructions Master your home Master your life ...

Страница 2: ... a home control App The Scene Master is ideal for kids elderlies and guests who may not have full access to your smart home s mobile application and hence may not have the rights to switch on various lighting heating air conditioning and other home appliance With a convenient snap in wall mount the ZRC 90 can also be removed to keep it handy while you go about your home for the ultimate in simple ...

Страница 3: ...imary and secondary controllers operating on the same system A Z Wave network has its own unique ID code so that controllers not in the network cannot control the system Scene A collection of Z Wave devices configured to turn to a specific level setting mode or perform an operation Scenes are usually activated by a controller timed event or specific conditions Primary Controller The first controll...

Страница 4: ...network To avoid inconsistency all node ID allocations are maintained by the SIS Inclusion Controller The SIS enables other controllers to include exclude nodes to from the network When SIS functionality is enabled the controller also takes the role as the Primary Controller because it has both latest network topology and allocated node IDs All the other controllers are called Inclusion Controller...

Страница 5: ...d control keys of ZRC 90 LED indication for Operation and Setup Wall mount bracket Scene control keyboard Setup buttons Upgrade header Upgrade slide switch Battery door Back block for plastic insert LED indication for Operation and Setup ...

Страница 6: ...D light up Create Primary Press the keys until LED light up Create Secondary Press the keys until LED light up Reset to factory default Press and keep holding 10 seconds then triple click Slide switch OP Normal operation default PC PC firmware upgrade mode The slide switch is designed for firmware upgrade by supplier please switch to OP direction for normal operation ...

Страница 7: ...hrough the following sections of this user manual and store for future reference ZRC 90 can be included and operated in any Z Wave network with other Z Wave certified devices from other manufacturers and or other applications All non battery operated devices within the network will act as repeaters regardless of vendor to increase reliability of the network ZRC 90 can act as a secondary Central Sc...

Страница 8: ...f if the command or operation is invalid Notes 1 If the device already existed into the network the unit will exit Learn mode automatically after 5 seconds 2 If the device does not exist into the network and no command from gateway the unit will exit Learn mode automatically after 30 seconds Scene activation and deactivation The real actions of scene will be depended on each gateway interpretation...

Страница 9: ...istening mode by click once on W button LED will keep flashes slowly 2 Listening mode will exit automatically after 30 seconds of inactivity LED stay off Notes 1 The mode must not be exited during communication process with another controller Please wait for entire communication process to be completed 2 It is not allowed to enter any user input from the remote s hard key after entry this mode ZRC...

Страница 10: ...etwork 3 In a Z Wave network only the primary controller or inclusion controller can add or include devices into its network If ZRC 90 is configured as a secondary controller it will report Error if users attempt to use ZRC 90 to add a device into its network 4 If no ACK signal received for more than 30 seconds the Add Device mode will exit automatically Removing Device from the Network Step Setup...

Страница 11: ...ller and ZRC 90 will act as a secondary controller This primary shift is done by following the steps below Step Setup Key Setup LED Indication on ZRC 90 1 Place the two controllers close to each other 2 Press W L buttons simultaneously until LED light up LED will keep flashes slowly 3 Please make sure the target primary controller is setup to receive information mode e g target primary controller ...

Страница 12: ...he Learn mode if this is a another ZRC 90 Please refer to the target controller user manual for more information Target secondary controller will act as a secondary controller after this action Original ZRC 90 primary controller will still keep in a primary controller after this action LED will flashes slowly until complete the step of Create a Secondary Controller Reset to factory default ZRC 90 ...

Страница 13: ...r electrical shock Do not mount to locations subject to high temperatures high humidity or exposure to water Doing so could cause a fire or electrical shock Do not mount to locations subject to large amounts of vibration large jolts or large forces These could cause an injury if the unit falls and breaks MOUNTING PROCEDURE PRECAUTIONS Do not modify parts or use the unit in ways other than its inte...

Страница 14: ...tenna direction 2 Before mounting to a wall be sure to fully read the precautions Mount to the wall bracket Dismount from wall bracket Figure 3 Installation Technical Specifications Model no BW8510US ZRC 90US BW8510EU ZRC 90EU BW8510AU ZRC 90AU BW8510RU ZRC 90RU BW8510IN ZRC 90IN BW8510IL ZRC 90IL BW8510JP ZRC 90JP RF frequency 908 42MHz ZRC 90US 868 42MHz ZRC 90EU 921 42MHz ZRC 90AU 869 02MHz ZRC...

Страница 15: ...m x 13 5mm Weight 60g main unit and batteries excluded 15g wall mount bracket Checking Accessories After opening the cover of the packing box check that the following accessories are included ZRC 90 Scene Master Plastic insert Wall mount bracket Wall anchor x 2pcs Screw x 2pcs User Manual Warranty sheet Scene label sheet Scene Reference List Scene Button Action in single click Action in double cli...

Страница 16: ...es tend to leak 3 Do not use corrosive or abrasive cleansers on your unit 4 Keep the unit dust free by wiping it with a soft dry cloth 5 Do not disassemble the unit it contains no user serviceable parts FCC Notice This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any...

Страница 17: ...d the user authority to operate the equipment Warnings Do not modify the unit in any way Risk of fire Risk of electrical shock Risk of burns Do not dispose of electrical appliances and unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available There is no user serviceable parts in this unit Use only power sup...

Отзывы: