Operation 

 

Inserting the batteries into the remote control

 

Prior to initial operation, the batteries supplied with the 
unit (2 type AAA batteries) must be inserted into the re-
mote control. 

1.  To do this, slide off the cover of the battery slot on 

the back of the remote control in the direction of the 
arrow. 

2.   Insert the batteries.       

Make sure that the polarity is correct, use the label-
ling in the slot. 

3.   Close the battery slot again. 

The remote control

 

Two to four seconds after the air-conditioning unit has 
been connected to the power supply you can begin op-
eration. The room air-conditioner is operated by means 
of the infrared remote control.  
Signals can only be transmitted properly at a maximum 
distance of approximately 7m. A beep indicates that a 
button has been pressed and the signal has been cor-
rectly received. 

1    On / Off button 

Press this button to put the unit into operation. The 
POWER display lights up.

 

2    Fan speed 

Set the fan speed you want with this button.  
There are 4 speeds available:          
automatic, low, medium and high.

 

3    Swing button 

When the unit is switched on (ON), the oscillating 
blade improves air distribution in the room.

 

4    Timer button

 

You can program the unit to automatically switch on 
or off within the next 24 hour-period with the timer.

 

5    Sleep button

 

If the Sleep function is activated, the set room tem-
perature increases by 1°C after one hour. This func-
tion can be reset by pressing any button.

 

6    Mode buttons 1 to 4

 

The room air-conditioner has 4 modes: 
1. Cooling mode: 
In this mode, the warm air in the room is cooled to 

the desired temperature. The COMP. display begins 
blinking for approx. 3 minutes (mechanism which 
stops the unit from switching back to prevent dam-
age to the compressor).

 

2. Dehumidification mode

In this mode, the room is primarily dehumidified but 
the set temperature is maintained. 
3. Heating mode:

 

This mode is not active for these models. 
4. Auto Heat mode:

 

These models work exclusively in cooling mode 
when automatic operation is activated.

 

7    Temp. button 

The Temperature button can be used to set the de-
sired temperature in 0.5°C increments between 15°C 
and 30°C. 

Manual operation 

The unit can be put into operation manually, e.g. if the 
remote control is not operating properly or is lost. For 
manual operation, press the POWER button on the up-
per right of the receiver (control panel) of the indoor 
unit. 
The following operating modes are then activated: 
MODE:         Automatic mode 
TEMP :         24°C 
FAN:              Automatic 
SWING:        On 
TIMER:         Off 

Содержание RKV 13 T

Страница 1: ...REMKO powerful like a bear REMKO RKV 13 T 24 T Wall Ceiling Chests Edition GB P05 Operation Technology Spare Parts...

Страница 2: ......

Страница 3: ...ctrical Connection 13 Condensation Connection 14 External Condensation Pump 15 Prior to Initial Operation 16 Initial Operation 17 Environment and Recycling 17 Customer Service and Guarantee 17 Certifi...

Страница 4: ...als Protect the indoor unit and the remote control from direct and indirect sunlight Do not expose the remote control to strong vibra tions Regularly check that condensation is not blocked from flowin...

Страница 5: ...oom 4 Timer button You can program the unit to automatically switch on or off within the next 24 hour period with the timer 5 Sleep button If the Sleep function is activated the set room tem perature...

Страница 6: ...e the COOL mode when you want to cool the room to the desired temperature Reduce the desired temperature by pressing the Temperature button in 0 5 C in crements After you hear a beep the COMP display...

Страница 7: ...room air conditioner is to be switched off at a later time press when of these buttons when the remote control is on In both operating modes 12 0H appears in the lower right hand corner of the displa...

Страница 8: ...ce left right 6 Closed the front of the unit Shutting Down the Unit Temporary shutdown 1 Switch all indoor units off using the remote control 2 Disconnect the system with the main switch or fuse prote...

Страница 9: ...batteries with the correct polarity Transmission distance too great reception blocked Is the transmission signal at a dis tance of approx 3 m when the but ton is pressed Reduce distance to under 6 m...

Страница 10: ...e line RKM Inch mm 1 4 6 35 Connection intake line RKM Inch mm 1 2 12 7 Additional amount to add 2 g m 18 15 Dehumidification capacity l h 1 0 2 0 Power supply V Hz 230 1 50 Hz supplied via outdoor pa...

Страница 11: ...blocked by furniture curtains etc Make sure that the electrical terminals have been properly attached The refrigerant lines may not be bent or pressed Protect open refrigerant lines from moisture with...

Страница 12: ...mm screws bolts as well as washers to the ceiling An incline of approx 8 mm to the connection adaptor must be maintained to ensure that the condensation can flow freely Wall mount Ceiling mount Insta...

Страница 13: ...lled The electrical installations may only be performed by author ised personnel in line with the relevant regulations Local guidelines for operation as well as the requirements es tablished by local...

Страница 14: ...information The condensation drainage line is generally placed in the same guideway as the refrigerant lines If as a result of structural design conditions it is necessary to have a different guidewa...

Страница 15: ...ed on Kondensatab laufschlauch Entl ftungsschlauch kurz Pumpe Reservoir Ansaugschlauch lang Tropfwanne Condensation drainage hose Ventilation house short Pump Collection tray Reservoir Suction hose lo...

Страница 16: ...he condensation pump Before putting the pump into operation the lines that have been laid must be checked to ensure that they are functioning properly and leakproof 1 Switch the power supply of the pu...

Страница 17: ...n mode and dehu midifying mode 6 Adjust the plate fins correctly to prevent air from be ing distributed unfavourably 7 Familiarise the operator with the system and give him the certificate for initial...

Страница 18: ...permeability check of the connections on the outdoor part and indoor unit s OK problem Shut off valves on the outdoor unit open if applicable OK problem Test run of unit operation Compressor fan outdo...

Страница 19: ......

Страница 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 E Mail info remko de Internet www remko de...

Отзывы: