Installation Instructions 

 
The standard unit is equipped with a connecting line be-
tween the indoor unit and the outdoor unit which makes 
it ready for operation. 

It comes with various accessories for assembling the out-
door unit. 

There  are  different  ways  to  set  up  the  indoor  unit  and 
outdoor  unit  which  are  described  in  the  following  sec-
tion. 
 

Indoor unit 

The  inner  unit  is  installed  in  the  desired  location  with 
the  air  outlet  side  facing  the  room. When  installing  the 
unit, make sure to comply with the safety instructions. 

Connecting line 

The  connecting  line  can  be  guided  to  the  outside 
through  a  partially  opened  window  or  door.  The  con-
necting line can be detached from the indoor unit which 
means  that  it  can  also  be  guided  through  a  wall  lead-
through (Ø min. 60 mm). 

When  laying  the  connecting  line,  follow  these  instruc-
tions: 

 

The connecting line may never be pinched or bent. 

 

The connecting line may  not be  pulled  or subject to 
any other mechanical force. 

 

To  prevent  the  formation  of  condensation,  the  hose 
insulation and the protective cover may not be dam-
aged. 

 

Outdoor unit 

The outdoor unit expels the heat transported out of the 
room  to  the  outside  air.  To  perform  this  function,  the 
outdoor  unit  can  either  be  placed  on  the  floor  or  hung 
on an outside wall. 
 
Floor installation 

To set up the outdoor unit on a terrace or balcony, it is not 
necessary to use fasteners. 

The  outdoor  unit  must  be  placed  horizontally  and  pro-
tected  from  direct  sunlight.  A  minimum  distance  of  20 
cm must be maintained between the air intake side and 
the wall. 

Air  must  be  able  to  flow  freely  out  of  the  unit  (min.  50 
cm  distance  to  other  objects).  The  connecting  line  is 
guided through an opening in a  door  or  window (Fig.  6 
and 7). 

Mounting on the outside wall with wall holder 

1.  Attach the supplied wall holders to the wall. 

2.  Hang the to outdoor unit in the wall holders and se-

cure it with the screws supplied M4 (Fig. 8 and 9). 

The  wall  holders  can  be  attached  with  the  fasteners 
supplied (dowel 6 mm and screws). If these are not suit-
able for the material the wall is made of, fastening units 
with adequate retention force are to be placed. 

When  mounting  the  holder,  make  sure  that  the  line  is 
not  placed  under  any  strain  and  that  the  insulation  is 
not damaged. 

Fig. 7 

Fig. 8 

 

There  must  be  a  minimum  of  20  cm  between  the 
back of the unit (air intake) and the wall. 

Fig. 6a 

Fig. 6 

20 cm 

20 cm 

 

Make sure to maintain the minimum distances. The 
air  coming  out  of  the  indoor  unit  and  the  outdoor 
unit may not be blocked. 

Содержание RKL 460

Страница 1: ...Operation Technology Spare Parts REMKO powerful like a bear REMKO RKL 460 RKL 480 RKL 480 S Line Portable Air Conditioner Edition GB T01...

Страница 2: ......

Страница 3: ...al Data 12 Wiring Diagram 13 Exploded View 14 Spare Part List 15 Service and Guarantee 15 Environment and Recycling 15 Portable Air Conditioner REMKO RKL 460 REMKO RKL 480 S Line Make sure to read the...

Страница 4: ...off by pressing the ON OFF but ton Do not switch the unit off by unplugging the power cable When unplugging the unit always pull the power plug Never pull the cable Do not set up or operate the unit...

Страница 5: ...ndoor unit or via the infrared remote control that comes with it The unit is particularly suited for flexible use The de tachable connecting line lets it be installed as a station ary unit Outdoor uni...

Страница 6: ...t temperature can be set as de scribed above 2 Unit switches off automatically When the device is on using the SET button the user can enter the number of hours after which the device is to be switche...

Страница 7: ...does not overflow This may cause water damage 10 Operating mode and fan setting display This display provides information about the operat ing mode and the fan setting which have been se lected 11 DRA...

Страница 8: ...to the outside air To perform this function the outdoor unit can either be placed on the floor or hung on an outside wall Floor installation To set up the outdoor unit on a terrace or balcony it is no...

Страница 9: ...to a wall or to a parapet in the outer area is to use straps 1 Hook the wall holders onto the outdoor unit and se cure them with the M4 safety screws Here the wall holders maintain the proper distance...

Страница 10: ...er pressure on the upper coupling with the second wrench SW 21 Fig 15 Never turn the inflexible upper part 12 Keep turning until the connection is detached Should refrigerant leak out with a slight hi...

Страница 11: ...lly in warm water 4 Then let the filter air dry 5 Reinsert the filter into the unit In case of extreme dirt the dust filter is to be replace Never use the unit without installed dust filter Without a...

Страница 12: ...gh Lower temperature Windows and doors open Thermal load increased Close windows and doors Reduce thermal load Condensation water leaks out of the unit The unit is not standing upright Place upright a...

Страница 13: ...FM1 Fan motor indoor unit FM2 Fan motor outdoor unit WM Water pump CM Compressor motor OLP Overload protection compressor CX1 Capacitor fan motor indoor unit CX2 Capacitor fan motor outdoor unit CX3...

Страница 14: ...oor unit 35 Indoor unit 1 42 11 32 12 10 13 2 13 14 37 34 27 26 25 17 19 18 36 22 23 20 21 39 38 24 7 9 8 35 33 31 28 30 6 3 4 41 40 16 5 15 29 We reserve the right to make modifications in dimensions...

Страница 15: ...122 8 Dust filter 1106067 Dust filter RKL 480 S Line 1106123 9 Cover connecting line 1106068 Cover connecting line RKL 480 S Line 1106124 10 Cover bottom 1106069 11 Base plate cpl 1106070 12 Transport...

Страница 16: ...REMKO GmbH Co KG Air Conditioning and Heating Technology D 32791 Lage Im Seelenkamp 12 D 32777 Lage P O Box 1827 Phone 49 52 32 606 0 Fax 49 52 32 606 260 E mail export remko de Internet www remko de...

Отзывы: