Installation Instructions
The standard unit is equipped with a connecting line be-
tween the indoor unit and the outdoor unit which makes
it ready for operation.
It comes with various accessories for assembling the out-
door unit.
There are different ways to set up the indoor unit and
outdoor unit which are described in the following sec-
tion.
Indoor unit
The inner unit is installed in the desired location with
the air outlet side facing the room. When installing the
unit, make sure to comply with the safety instructions.
Connecting line
The connecting line can be guided to the outside
through a partially opened window or door. The con-
necting line can be detached from the indoor unit which
means that it can also be guided through a wall lead-
through (Ø min. 60 mm).
When laying the connecting line, follow these instruc-
tions:
◊
The connecting line may never be pinched or bent.
◊
The connecting line may not be pulled or subject to
any other mechanical force.
◊
To prevent the formation of condensation, the hose
insulation and the protective cover may not be dam-
aged.
Outdoor unit
The outdoor unit expels the heat transported out of the
room to the outside air. To perform this function, the
outdoor unit can either be placed on the floor or hung
on an outside wall.
Floor installation
To set up the outdoor unit on a terrace or balcony, it is not
necessary to use fasteners.
The outdoor unit must be placed horizontally and pro-
tected from direct sunlight. A minimum distance of 20
cm must be maintained between the air intake side and
the wall.
Air must be able to flow freely out of the unit (min. 50
cm distance to other objects). The connecting line is
guided through an opening in a door or window (Fig. 6
and 7).
Mounting on the outside wall with wall holder
1. Attach the supplied wall holders to the wall.
2. Hang the to outdoor unit in the wall holders and se-
cure it with the screws supplied M4 (Fig. 8 and 9).
The wall holders can be attached with the fasteners
supplied (dowel 6 mm and screws). If these are not suit-
able for the material the wall is made of, fastening units
with adequate retention force are to be placed.
When mounting the holder, make sure that the line is
not placed under any strain and that the insulation is
not damaged.
Fig. 7
Fig. 8
There must be a minimum of 20 cm between the
back of the unit (air intake) and the wall.
Fig. 6a
Fig. 6
20 cm
20 cm
Make sure to maintain the minimum distances. The
air coming out of the indoor unit and the outdoor
unit may not be blocked.