Safety Instructions 

 
Extensive  tests  have  been  conducted  on  the  material, 
functionality and quality of the REMKO portable air con-
ditioner to ensure that it is a high-performance unit with 
a long service life. 

Hazards  may  nevertheless  arise  if  the  unit  is  used  by 
persons not familiar with its operation or if the unit is not 
used for its intended purpose. 

Please  also  make  sure  to  follow  these  safety  instruc-
tions. 

 

The  indoor  unit  is  not  suitable  for  operation  out-
doors! 

 

The unit may only be operated within the permissible 
range of uses!   
Pay attention to surrounding temperatures. 

 

Ensure that the unit is set up at a safe distance from 
flammable materials. 

 

Do not set the unit up near curtains or drapes. 

 

Maintain a safety zone of at least 50 cm around the 
unit. 

 

Ensure that the air intake and outlet openings are al-
ways clear of foreign objects. 

 

Ensure that the air conditioner is securely placed on 
a level surface.  
The unit may only be operated in an upright position. 

 

Do not use the unit  if it  is lying  on  its side or  in  any 
manner deviating from these instructions. 

 

Do  not  insert  any  foreign  objects  into  the  air  intake 
or outlet openings 

 

Do  not  place  any  heavy  or  warm  objects  on  top  of 
the unit. 

 

Empty the water tank before moving the unit. 

 

This  unit  may  only  be  connected  to  a  correctly  in-
stalled, grounded and fused plug socket.   
230V / 50 Hz; 10A fuse. 

 

Do  not  pull  on  the  power  cable  or  bend  it  exces-
sively. 

 

This may result in damage to the cable. 

 

Do not move the unit while in operation. Wait at least 
five minutes before starting the unit after it has been 
moved.   
This may result in damage to the compressor. 

 

Switch  the  unit  off  by  pressing  the  ON/OFF  but-
ton.Do  not  switch  the  unit  off  by  unplugging  the 
power cable.
 

 

When  unplugging  the  unit,  always  pull  the  power 
plug. Never pull the cable. 

 

Do not set up or operate the unit in rooms containing 
explosion hazards. 

 

Do not set up or operate the unit in rooms containing 
explosion hazards. 

 

Do not expose the unit to direct streams of water. 

 

Protect all cables from damage. 

 

Make  sure  that  all  extension  cables  are  suitable  in 
terms of capacity, length and intended use. 

 

Do not lay any cables under carpets or rugs! 

 

Never open the unit housing! 

 

 

This may cause an electric shock! 

 

Repairs  may  only  be  performed  by  authorised  per-
sonnel! 

 

Never  use  the  unit  without  the  dust  filter  installed! 
Without a dust filter, the plate fins of the evaporators 
become dirty and performance of the unit suffers. 

 

Never aim the air current directly at people! 

 

The  unit  should  only  be  installed  by  a  specialised 
company. 

Transport and Packaging 

 
The device is shipped in a stable transport box made of 
cardboard. Please examine the unit when it is delivered 
and make note of any  damage or missing parts on the 
shipping bill. 

Please observe the following for transport: 

 

Before transporting the unit, switch it off on the con-
trol panel and unplug the power cable. 

 

The unit may only be transported in an upright posi-
tion. 

 

The  indoor  unit  is  equipped  with  wheels  to  make 
transport easier. The outdoor unit can be hooked on 
to the back of the indoor unit for transport. 

 

Make  sure  that  the  connection  line  does  not  have 
any kinks. 

 

Empty the water tank prior to transport by means of 
the drainage tube on the back of the unit. 

 

When  the  unit  is  in  operation,  do  not  switch  it  off 
directly  at  the  power  supply  by  unplugging  it  as 
this may damage the control circuit and invalidate 
the warranty.  Always switch the  unit  on and off at 
the control panel. 

Содержание RKL 460

Страница 1: ...Operation Technology Spare Parts REMKO powerful like a bear REMKO RKL 460 RKL 480 RKL 480 S Line Portable Air Conditioner Edition GB T01...

Страница 2: ......

Страница 3: ...al Data 12 Wiring Diagram 13 Exploded View 14 Spare Part List 15 Service and Guarantee 15 Environment and Recycling 15 Portable Air Conditioner REMKO RKL 460 REMKO RKL 480 S Line Make sure to read the...

Страница 4: ...off by pressing the ON OFF but ton Do not switch the unit off by unplugging the power cable When unplugging the unit always pull the power plug Never pull the cable Do not set up or operate the unit...

Страница 5: ...ndoor unit or via the infrared remote control that comes with it The unit is particularly suited for flexible use The de tachable connecting line lets it be installed as a station ary unit Outdoor uni...

Страница 6: ...t temperature can be set as de scribed above 2 Unit switches off automatically When the device is on using the SET button the user can enter the number of hours after which the device is to be switche...

Страница 7: ...does not overflow This may cause water damage 10 Operating mode and fan setting display This display provides information about the operat ing mode and the fan setting which have been se lected 11 DRA...

Страница 8: ...to the outside air To perform this function the outdoor unit can either be placed on the floor or hung on an outside wall Floor installation To set up the outdoor unit on a terrace or balcony it is no...

Страница 9: ...to a wall or to a parapet in the outer area is to use straps 1 Hook the wall holders onto the outdoor unit and se cure them with the M4 safety screws Here the wall holders maintain the proper distance...

Страница 10: ...er pressure on the upper coupling with the second wrench SW 21 Fig 15 Never turn the inflexible upper part 12 Keep turning until the connection is detached Should refrigerant leak out with a slight hi...

Страница 11: ...lly in warm water 4 Then let the filter air dry 5 Reinsert the filter into the unit In case of extreme dirt the dust filter is to be replace Never use the unit without installed dust filter Without a...

Страница 12: ...gh Lower temperature Windows and doors open Thermal load increased Close windows and doors Reduce thermal load Condensation water leaks out of the unit The unit is not standing upright Place upright a...

Страница 13: ...FM1 Fan motor indoor unit FM2 Fan motor outdoor unit WM Water pump CM Compressor motor OLP Overload protection compressor CX1 Capacitor fan motor indoor unit CX2 Capacitor fan motor outdoor unit CX3...

Страница 14: ...oor unit 35 Indoor unit 1 42 11 32 12 10 13 2 13 14 37 34 27 26 25 17 19 18 36 22 23 20 21 39 38 24 7 9 8 35 33 31 28 30 6 3 4 41 40 16 5 15 29 We reserve the right to make modifications in dimensions...

Страница 15: ...122 8 Dust filter 1106067 Dust filter RKL 480 S Line 1106123 9 Cover connecting line 1106068 Cover connecting line RKL 480 S Line 1106124 10 Cover bottom 1106069 11 Base plate cpl 1106070 12 Transport...

Страница 16: ...REMKO GmbH Co KG Air Conditioning and Heating Technology D 32791 Lage Im Seelenkamp 12 D 32777 Lage P O Box 1827 Phone 49 52 32 606 0 Fax 49 52 32 606 260 E mail export remko de Internet www remko de...

Отзывы: