9
6.11. Compressed air is a flow of energy, and for this reason it is associated with a po-
tential danger. Pipelines, containing the compressed air, should be in working condition and
plugged correspondingly. Before increasing pressure in the flexible lines, one should make
sure, that their rags are well fixed.
6.12. Do not use the flexible lines for the instruments’ shift.
6.13. To move the compressor (switched off) the handle located on the receiver should
be used.
6.14. Before starting the device one should check up the following:
- accuracy of connection to the power supply source and to earth.
-
integrity and reliability of the protection enclosure of the wedge-type drive fastening.
-
reliability of the compressor’s supports fastening.
- integrity and good order of the safety valves and operating controls.
6.15. For technical testing one should use the present manual, as well as “Regula-
tions on the electric installations” and “Regulations on the safe exploitation of the vessels
under pressure”.
6.16. After completing the rehabilitation the operator should place the protective en-
closure and all other details, by this one should observe the same safety measures, as by the
first start.
6.17. Safety measures by operating of the receiver.
-
Properly use the receiver within the limits of pressure and temperature, stated on the
shield with technical data of the manufacturer.
-
Constantly control the serviceability and efficacy of the protective and controlling de-
vices (pressostate, safety valve, manometers).
-
Do not place receiver in premises with poor ventilation facilities, and in zones, exposed
to heat and flammable materials.
-
Do not expose the receiver to vibrations, which can lead to breakage of the welds, be-
cause of the metal’s fatigue strength.
-
Every day one should discharge condensate, which is generated in receiver.
When operating the receiver, one should observe the requirements of “Regulations
on the system and safe exploitation of the vessels under pressure”.
6.18. The equivalent of the sound level in the operator’s working zone within 1,0 m
from the compressor, provided the coefficient of usage is 0,6, should not exceed 80 decibel.
6.19. When the noise level exceeds normal level, than it is necessary to use the means
of individual protection.
6.20. The cargo handling procedures should be carried out according to transport marks
on the container.
6.21. Recycling of the used oils and condensates should be carried out with observance
of the appropriate specifications, because these products pollute the environment.
6.22. While operating the compressor one should observe “General fire prevention rules
for the industrial enterprises … ".
It is forbidden:
- To operate the compressor with the faulty or switched - off protection against cur-
rents of short circuit and thermal protection;
Содержание SB4/C-100.LB75
Страница 1: ...COMPRESSOR SB4 C 100 LB75 SB4 F 270 LB75 SB4 F 500 LB75 SB4 F 270 LB75V MANUAL ISO 9001 2008...
Страница 2: ...2...
Страница 16: ...16...