It is necessary to underline, that even the rotation of the engine in the opposite 

direction during very short period of time can cause severe damages.

 

7.8. Reliably connect the compressor to the consumers of compressed air, using the 

appropriate pneumoapparatus and pipelines.

 

7.9. By the first start, and also after the long period of inactivity, it is recommended 

to add some drops of compressor oil to the air filter.

 

7.10. Start-up and stop of the compressor should be carried out only by means of the 

switch on pressostate. After starting-up the compressor, while air is used by the consumer, 
the relay of pressure of the pressostate automatically switches off and on, maintaining the 
pressure of compressed air in the receiver within the given limits - (1,0... 0,8) MPa. At the 
first start-up, and also at each repeated switching  check the conformity of the direction of 
rotation  specified  on  a  protective  enclosure  of  wedge-belt  transmission  and  the  pulley  of 
the compressor’s unit.

 

7.11. The relay of pressure (pressostate) is adjusted by the manufacturer, and should 

not be readjusted by the user.

 

The adjustment of pressure of compressed air at the output is carried out by a regula-

tor of pressure as follows:

 

- with the spigot being open it is necessary to pull the handle of a regulator of pres-

sure  upwards  and  to  rotate  it  clockwise  in  order  to  increase  the  pressure  or  counter-
clockwise to reduce pressure;

 

- After checking the given value of pressure according to manometer, it is necessary 

to press the handle, thus having fixed the chosen value;

 

The amount of processed air depends on pressure in receiver and on its consumption 

- at a superfluous consumption the manometer displays low values.

 

7.12.  The  compressor  is  equipped  with  the  device  of  thermal  protection  against  over-

loads.  During  long  periods  of  operation  and  overconsumption  of  compressed  air  automatic 
switching-off of the compressor due to its overheating is possible.

 

After the engine cools down to a tolerable temperature, turn off the switch located on 

the pressostate’s case, the device of thermal protection is then switched on. 

 

In order to prevent failure of the engine, the intervention in system of thermal protec-

tion is intolerable. 

 

7.13. For correct usage and normal work of the compressor it is necessary to take 

into account, that the nominal operation mode is as follows: intermittent with duration 
of switched-on periods (SP 60 %) and number of swithched-on periods within one hour 
– not more than 60.

 

7.14. After the complete switching-off let out the air from the receiver.

 

 
 
 
 
 
 
 
 
 
 

Содержание SB4/C-100.LB75

Страница 1: ...COMPRESSOR SB4 C 100 LB75 SB4 F 270 LB75 SB4 F 500 LB75 SB4 F 270 LB75V MANUAL ISO 9001 2008...

Страница 2: ...2...

Страница 3: ...es exposed to rain and for household purposes 2 2 The power supply of the compressor is provided by means of an alternate current power supply source with the voltage 400 V and the frequency 50 1 25 H...

Страница 4: ...characteristics of wedge type belt are listed in table 2 Table 2 Name and marking Quant Notes Belt 1600 2 3 6 Characteristics of the electrical equipment are listed in table 3 Table 3 Name and markin...

Страница 5: ...shed through an aperture in the crater s bottom which is blanked with the cap Receiver 1 see pic 1 2 3 4 serves for collecting of compressed air avoidance of pressure pulsation condensate and oil segr...

Страница 6: ...the compressor SB4 C 100 LB75 i 1 General view of the compressor SB4 F 270 LB75 LB75 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 LB75 ic 2 General view of the compresso...

Страница 7: ...7 Pic 4 Principal electric circuit General view of the compressor SB4 F 270 LB75 LB75 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 LB75 9 10 11 12 13 14 15 Hz 400...

Страница 8: ...solvent or dye spray toxic smoke of any type 6 7 In case the compressor is situated in a room of critical condition presence of dust particle of different types it is necessary to change filters more...

Страница 9: ...d temperature stated on the shield with technical data of the manufacturer Constantly control the serviceability and efficacy of the protective and controlling de vices pressostate safety valve manome...

Страница 10: ...compressor should be made by the trained personnel which carries out various kinds of the control according to the instruc tions 7 3 Accurately open the package check up completeness make sure of the...

Страница 11: ...a regula tor of pressure as follows with the spigot being open it is necessary to pull the handle of a regulator of pres sure upwards and to rotate it clockwise in order to increase the pressure or co...

Страница 12: ...ten if the premises are dusty Reduction of the capacity of the air filter reduces service life of the compressor in creases the consumption of the electric power and can result in breakup Merge conden...

Страница 13: ...ine shutdown in the process of op eration Malfunction of the engine s ventilator Check the ventilator change it if necessary Insufficient level of oil in the compressor s casing Check the quality and...

Страница 14: ...of the col umns of the unit 12 of the present passport Date of sale The seller s data Seal of the vendor 10 5 The buyer loses the right of warranty service in case of loss of the passport completely b...

Страница 15: ...______________________________________________________ the compressor unit found ready for service Packaging was done by _________________________ Manufacture date _____ __________________ 20 y QCD ma...

Страница 16: ...16...

Страница 17: ...ame and signature of the seller Seal of the seller Warranty period is ________________________months from the date of sale The article was tested in the following operation modes______________________...

Страница 18: ...y guarantee seals on the device and non authorized ac cess to the device s settings 5 Application of spare parts and materials which have been not stipulated by the opera tional documentation 6 Infrin...

Отзывы: