11
It is necessary to underline, that even the rotation of the engine in the opposite
direction during very short period of time can cause severe damages.
7.8. Reliably connect the compressor to the consumers of compressed air, using the
appropriate pneumoapparatus and pipelines.
7.9. By the first start, and also after the long period of inactivity, it is recommended
to add some drops of compressor oil to the air filter.
7.10. Start-up and stop of the compressor should be carried out only by means of the
switch on pressostate. After starting-up the compressor, while air is used by the consumer,
the relay of pressure of the pressostate automatically switches off and on, maintaining the
pressure of compressed air in the receiver within the given limits - (1,0... 0,8) MPa. At the
first start-up, and also at each repeated switching check the conformity of the direction of
rotation specified on a protective enclosure of wedge-belt transmission and the pulley of
the compressor’s unit.
7.11. The relay of pressure (pressostate) is adjusted by the manufacturer, and should
not be readjusted by the user.
The adjustment of pressure of compressed air at the output is carried out by a regula-
tor of pressure as follows:
- with the spigot being open it is necessary to pull the handle of a regulator of pres-
sure upwards and to rotate it clockwise in order to increase the pressure or counter-
clockwise to reduce pressure;
- After checking the given value of pressure according to manometer, it is necessary
to press the handle, thus having fixed the chosen value;
The amount of processed air depends on pressure in receiver and on its consumption
- at a superfluous consumption the manometer displays low values.
7.12. The compressor is equipped with the device of thermal protection against over-
loads. During long periods of operation and overconsumption of compressed air automatic
switching-off of the compressor due to its overheating is possible.
After the engine cools down to a tolerable temperature, turn off the switch located on
the pressostate’s case, the device of thermal protection is then switched on.
In order to prevent failure of the engine, the intervention in system of thermal protec-
tion is intolerable.
7.13. For correct usage and normal work of the compressor it is necessary to take
into account, that the nominal operation mode is as follows: intermittent with duration
of switched-on periods (SP 60 %) and number of swithched-on periods within one hour
– not more than 60.
7.14. After the complete switching-off let out the air from the receiver.
Содержание SB4/C-100.LB75
Страница 1: ...COMPRESSOR SB4 C 100 LB75 SB4 F 270 LB75 SB4 F 500 LB75 SB4 F 270 LB75V MANUAL ISO 9001 2008...
Страница 2: ...2...
Страница 16: ...16...