10
- To bring in any changes to electrical or pneumatic circuits of the compressor or
their settings. In particular to change the value of the maximal pressure of compressed air
and settings of the safety valve;
-To turn on the compressor with removed protection of wedge-belt transmission;
-While operating the compressor to touch heated details (head and block of cylin-
ders, heat pump, details of the force air-pump, electric motor’s cooling fans);
-To carry out machining or welding of the receiver. In case of defects or corrosion it
is necessary to replace it completely, as it falls under the special norms of safety;
-to touch the compressor with wet hands or to work in wet footwear;
-To direct a jet of compressed air at oneself or other people around;
-To let children and animals into the working area;
-To carry out coloring in a non-aired premises or near open flame;
-To store kerosene, petrol and other inflammable liquids at the site of the com-
pressor’s installation;
-To leave the compressor, which is plugged to the mains, without supervision;
-To carry out repair works of the compressor, which is plugged to the mains,
and when the pressure in the receiver is not releived;
-To transport the compressor, which is under pressure.
7. Pre-starting and operating procedures
7.1. Study the instructions of the present passport attentively and follow them.
7.2. It is important, that the first start of the compressor should be made by the
trained personnel, which carries out various kinds of the control according to the instruc-
tions.
7.3. Accurately open the package, check up completeness, make sure of the absence
of damages.
7.4. Mount wheels and shock-absorbers onto the receiver, mount the compressor on
an even horizontal platform, ensuring in this way an easy approach to the switch and spigot
of air supply to the consumer. For good ventilation and effective cooling it is necessary that
the protections of belt transfer were at a minimum distance of 1 meter from a wall. The
floor of the premises at an installation site of the compressor should be made from a fire-
proof and oil proof material.
7.5. Check up the conformity of the instructions shields on the unit of the compres-
sor, receiver, electric motor and data of the present passport.
7.6. Check up on the oil indicator the level of oil in crank case of the compressor’s
module - it should be within the limits of a red mark on a watching glass. If necessary, add
some oil up to the average level, choose oil according recommendations in the present
instruction. Do not allow outflow of oil from junctures and onto the outside surfaces of the
compressor.
7.7. Check up conformity of the voltage of a power-supply mains with the re-
quirements of the paragraph 2.2 of the present operation manual.
In the case of electrical connection the sequence of phases is of importance, as it
determines the direction of rotation, which should correspond to the direction, speci-
fied by the pointer on a protection enclosure of the wedge-belt transmission.