- To bring in any changes to electrical or pneumatic circuits of the compressor or 

their settings. In particular to change the value of the maximal pressure of compressed air 
and settings of the safety valve;

 

-To turn on the compressor with removed protection of wedge-belt  transmission;

 

-While operating  the compressor to touch heated details (head and block of cylin-

ders, heat pump, details of the force air-pump, electric motor’s cooling fans);

 

-To carry out machining or welding of the receiver. In case of defects or corrosion it 

is necessary to replace it completely, as it falls under the special norms of safety; 

 

-to touch the compressor with wet hands or to work in wet footwear;

 

-To direct a jet of compressed air at oneself or other people around;

 

-To let children and animals into the working area;

 

-To carry out coloring in a non-aired premises or near open flame;

 

-To store kerosene, petrol and other inflammable liquids at the site of the com-

pressor’s  installation;

 

-To leave the compressor, which is plugged to the mains, without supervision;

 

-To carry out repair works of the compressor, which is plugged to the mains, 

and when the  pressure in the receiver is not releived;

 

-To transport the compressor, which is under pressure.

 

 
 

7. Pre-starting and operating procedures

 

 

7.1. Study the instructions of the present passport attentively and follow them. 
7.2.  It  is  important,  that  the  first  start  of  the  compressor  should  be  made  by  the 

trained  personnel, which  carries  out various kinds  of the  control  according  to  the  instruc-
tions. 

7.3. Accurately open the package, check up completeness, make sure of the absence 

of damages. 

7.4. Mount wheels and shock-absorbers onto the receiver, mount the compressor on 

an even horizontal platform, ensuring in this way an easy approach to the switch and spigot 
of air supply to the consumer. For good ventilation and effective cooling it is necessary that 
the  protections  of  belt  transfer  were  at  a  minimum  distance  of  1  meter  from  a  wall.  The 
floor of the premises at an installation site of the compressor should be made from a fire-
proof and oil proof material. 

7.5. Check up the conformity of the instructions shields on the unit of the compres-

sor, receiver, electric motor and data of the present passport. 

7.6. Check up on the oil indicator the level of oil in crank case of the compressor’s 

module - it should be within the limits of a red mark on a watching glass. If necessary, add 
some  oil  up  to  the  average  level,  choose  oil  according  recommendations  in  the  present     
instruction. Do not allow outflow of oil from junctures and onto the outside surfaces of the 
compressor.

 

7.7.  Check  up  conformity  of  the  voltage  of  a  power-supply  mains  with  the  re-

quirements of the paragraph 2.2 of the present operation manual. 

 

In the case of electrical connection the sequence of phases is of importance, as it 

determines the direction of rotation, which should correspond to the direction, speci-
fied by the pointer on a protection enclosure of the wedge-belt transmission.

 

Содержание SB4/C-100.LB75

Страница 1: ...COMPRESSOR SB4 C 100 LB75 SB4 F 270 LB75 SB4 F 500 LB75 SB4 F 270 LB75V MANUAL ISO 9001 2008...

Страница 2: ...2...

Страница 3: ...es exposed to rain and for household purposes 2 2 The power supply of the compressor is provided by means of an alternate current power supply source with the voltage 400 V and the frequency 50 1 25 H...

Страница 4: ...characteristics of wedge type belt are listed in table 2 Table 2 Name and marking Quant Notes Belt 1600 2 3 6 Characteristics of the electrical equipment are listed in table 3 Table 3 Name and markin...

Страница 5: ...shed through an aperture in the crater s bottom which is blanked with the cap Receiver 1 see pic 1 2 3 4 serves for collecting of compressed air avoidance of pressure pulsation condensate and oil segr...

Страница 6: ...the compressor SB4 C 100 LB75 i 1 General view of the compressor SB4 F 270 LB75 LB75 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 LB75 ic 2 General view of the compresso...

Страница 7: ...7 Pic 4 Principal electric circuit General view of the compressor SB4 F 270 LB75 LB75 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 LB75 9 10 11 12 13 14 15 Hz 400...

Страница 8: ...solvent or dye spray toxic smoke of any type 6 7 In case the compressor is situated in a room of critical condition presence of dust particle of different types it is necessary to change filters more...

Страница 9: ...d temperature stated on the shield with technical data of the manufacturer Constantly control the serviceability and efficacy of the protective and controlling de vices pressostate safety valve manome...

Страница 10: ...compressor should be made by the trained personnel which carries out various kinds of the control according to the instruc tions 7 3 Accurately open the package check up completeness make sure of the...

Страница 11: ...a regula tor of pressure as follows with the spigot being open it is necessary to pull the handle of a regulator of pres sure upwards and to rotate it clockwise in order to increase the pressure or co...

Страница 12: ...ten if the premises are dusty Reduction of the capacity of the air filter reduces service life of the compressor in creases the consumption of the electric power and can result in breakup Merge conden...

Страница 13: ...ine shutdown in the process of op eration Malfunction of the engine s ventilator Check the ventilator change it if necessary Insufficient level of oil in the compressor s casing Check the quality and...

Страница 14: ...of the col umns of the unit 12 of the present passport Date of sale The seller s data Seal of the vendor 10 5 The buyer loses the right of warranty service in case of loss of the passport completely b...

Страница 15: ...______________________________________________________ the compressor unit found ready for service Packaging was done by _________________________ Manufacture date _____ __________________ 20 y QCD ma...

Страница 16: ...16...

Страница 17: ...ame and signature of the seller Seal of the seller Warranty period is ________________________months from the date of sale The article was tested in the following operation modes______________________...

Страница 18: ...y guarantee seals on the device and non authorized ac cess to the device s settings 5 Application of spare parts and materials which have been not stipulated by the opera tional documentation 6 Infrin...

Отзывы: