background image

2. Put the domestic hot water tank in position and tilt on the ground. 

Note

Be careful to lift the domestic hot water tank slightly in order not to 

damage the bottom of the panels.

3. Level the domestic hot water tank with the adjustable feet. 

a

Adjustment range: 10 to 20 mm from the floor

Fig.8

Positioning the domestic hot water 

tank

MW-4000021-1

2

Fig.9

Levelling the domestic hot water tank

MW-4000022-2

a

3

5  Before installation

18

EL 110 SL

7626247 - v03 - 29042016

Содержание EL 110 SL

Страница 1: ...MW 4000029 3 en Installation User and Service Manual Domestic hot water tank EL 110 SL...

Страница 2: ...ng the product and keep it in a safe place for future reference In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained Our Service and After Sa...

Страница 3: ...ation 15 5 2 Installation requirements 15 5 2 1 Water operating pressure 15 5 2 2 Domestic water quality 15 5 3 Choice of the location 16 5 3 1 Data plate 16 5 3 2 Overall space needed for the domesti...

Страница 4: ...List of standard maintenance operations to be performed 27 8 2 2 Removing and remounting the inspection hatch 27 8 2 3 Checking the safety valve or unit 28 8 2 4 Checking the magnesium anode 28 8 2 5...

Страница 5: ...ied professionals are authorised to work on the domestic hot water tank and the heating installa tion Note Allow the space required to install the appliance cor rectly referring to the chapter Dimensi...

Страница 6: ...80 of the safety valve or safety unit calibration and must be located up stream of the appliance Caution There must be no cut off devices between the safety valve or unit and the domestic hot water ta...

Страница 7: ...ater tank service Note This manual can also be found on our internet site 1 2 Recommendations Caution Do not neglect to service the domestic hot water tank Contact a qualified professional or take out...

Страница 8: ...ation service and user manual 1 4 Liabilities 1 4 1 Manufacturer s liability Our products are manufactured in compliance with the re quirements of the various Directives applicable They are therefore...

Страница 9: ...er 1 4 3 User s liability To guarantee optimum operation of the system you must abide by the following instructions Read and follow the instructions given in the manuals pro vided with the appliance C...

Страница 10: ...jury Danger of electric shock Risk of electric shock Warning Risk of dangerous situations that may result in minor personal in jury Caution Risk of material damage Note Please note important informati...

Страница 11: ...time of installation 3 2 Technical data 3 2 1 Domestic hot water tank Tab 1 Heating water circuit Unit EL 110 SL Maximum operating temperature C 95 Maximum operating pressure bar MPa 3 0 3 Exchanger...

Страница 12: ...sensor specifications Tab 6 Sensor specifications Temperature in C 10 20 25 30 40 50 60 70 80 Resistance in ohms 19691 12474 10000 8080 5372 3661 2536 1794 1290 3 2 4 Specifications of the magnesium a...

Страница 13: ...lorofluorocarbon free polyur ethane foam which helps to reduce heat losses to a minimum The outside casing is made of painted steel sheets This domestic hot water tank is offered exclusively as a pack...

Страница 14: ...d cover One data plate Boiler retaining screws An instructions bag containing Adjustable feet One drain valve One domestic hot water sensor One screws bag Clips One installation user and service manua...

Страница 15: ...the prevailing standards and regulations in the country concerned 5 2 Installation requirements 5 2 1 Water operating pressure The tanks on our domestic hot water heaters can run at a maximum oper at...

Страница 16: ...stall the domestic hot water tank beneath the boiler To ascertain the space to be allowed around the domestic hot water tank in order to facili tate access and maintenance refer to the boiler s instal...

Страница 17: ...Remove the protective packaging 5 4 2 Positioning the domestic hot water tank Have two people available Handle and manoeuvre the domestic hot water tank with gloves 1 Screw the 4 adjustable feet to t...

Страница 18: ...n order not to damage the bottom of the panels 3 Level the domestic hot water tank with the adjustable feet a Adjustment range 10 to 20 mm from the floor Fig 8 Positioning the domestic hot water tank...

Страница 19: ...over 2 Put the domestic hot water sensor in place 3 Put the insulated cover back in place feeding the sensor cable through the notches in the cover 6 2 2 Mounting the front panel 1 Slide the clips pro...

Страница 20: ...ves 1 Install the boiler on the front of the domestic hot water tank taking care to correctly align the side panels of the boiler and the domestic hot water tank 2 Secure the boiler to the domestic ho...

Страница 21: ...low of domestic hot water into the do mestic cold water circuit 5 Incorporate a sealed safety valve calibrated to 7 bar 0 7 MPa not provided on the domestic cold water inlet close to the tank in a po...

Страница 22: ...re made of copper fit a sleeve made of steel cast iron or any other insulating material between the domestic hot water tank s DHW outlet and the pipes to prevent corrosion to the connection Caution Li...

Страница 23: ...itted with a main switch 6 4 2 Connecting the domestic hot water sensor 1 Connect the domestic hot water sensor to the S ECS output on ter minal block on the boiler See Boiler installation and service...

Страница 24: ...n return valve 50 Disconnector 51 Thermostatic valve 1 Open the caps on the 2 air vents 2 Fill through the system s return 3 Pressurise approximately 0 2 MPa 2 bar 4 Switch on the boiler A venting cyc...

Страница 25: ...erformed automatically and lasts approximately 3 minutes 6 Repeat steps 4 and 5 until the coil is thoroughly vented 7 Add water to the coil circuit if necessary 8 Set the screw on the anti thermosipho...

Страница 26: ...rfectly normal and must in no cir cumstances be hindered Note Have the domestic hot water tank commissioned at the same time as the boiler See Boiler installation and maintenance manual 7 2 1 Commissi...

Страница 27: ...ligatory Schedule servicing of the domestic hot water tank at the same time as the boiler 1 Check the safety valve or unit 2 Check the magnesium anode 3 Descale the domestic hot water tank For more in...

Страница 28: ...ure to follow this maintenance requirement may lead to the de terioration of the domestic hot water tank and void its warranty Caution The outlet pipe in the safety valve or unit must not be blocked F...

Страница 29: ...the tank as it provides effective protection against corrosion and improves the insulation of the domestic hot water tank 3 Remove limescale deposits from the exchanger to guarantee its per formance 4...

Страница 30: ...tank must be done by a qualified professional in compliance with prevailing local and national regulations 1 Disconnect the anode where one is connected 2 Cut the electrical power to the boiler 3 Clo...

Страница 31: ...d views Fig 23 Domestic hot water tank 13 1 2 4 10 3 MW 4000028 3 9 15 16 11 12 5 6 8 7 17 11 14 19 18 Markers Reference Description 1 7609915 Domestic hot water tank EL 110 SL 2 200022433 Inspection...

Страница 32: ...023263 Trim panel 13 97581059 Adjustable foot 8x25 14 95770692 Screw EC CB 7x12 7 15 300008957 2 pin connector 16 95362447 KVT60 sensor length 2 m 17 95320780 Clamp 18 200021501 Inspection hatch fitti...

Страница 33: ...able for material damage intangible los ses or physical injury resulting from an installation that does not comply with Legal or regulatory requirements or provisions laid down by the local au thoriti...

Страница 34: ...11 Warranty 34 EL 110 SL 7626247 v03 29042016...

Страница 35: ...nological information contained in these technical instructions as well as any drawings and technical de scriptions supplied remain our property and shall not be multiplied without our prior consent i...

Страница 36: ...7626247 v03 29042016 7626247 001 03...

Отзывы: