4 - GENERAL PARAMETERS, DESCRIPTION
49'1329 e
GV3000/SE
4 - 3
GENERAL PARAMETERS (P.xxx) - First Menu List
P.000
Control Source
Parameter Range:
LOCL = Local keypad/display
rE
= Terminal strip remote inputs
OP
= Option port (InterBus, Profibus-DP, ControlNet, DeviceNet, AMX network)
SErL = Serial port (CS3000 or OIM*)
Initial Setting:
LOCL
Type:
Configurable (in standby only)
Refer to:
P.007 Terminal Strip Digital Inputs Configure
P.008 Terminal Strip Speed Reference Source
P.063 Option Port: Network Reference Source
Description:
This parameter selects the drive control source.
The drive responds to the reference, forward/reverse, run/ jog, and start commands
(inputs) only from the source selected in this parameter.
If LOCL is selected, all commands come directly from the front panel keypad.
If REMOTE is selected, the controller will follow commands from the terminal strip
remote inputs. The REMOTE LED on the keypad front panel will light.
STOP/RESET key at keypad is effective for all control sources.
Note: The
REMOTE
LED will turn ON if any control source other than LOCL is selected.
WARNING
In V/Hz regulation, if P.000 (Control Source Select) is set to OP (Option Port), and P.062 is set to 1
(Hold last reference), and the drive loses communication with the network, the drive will maintain the last
frequency command sent to it. Ensure that driven machinery, all drive-train mechanisms, and process
line material are capable of safe operation at the maximum operating speed of the drive. Failure to
observe this precaution could result in bodily injury.
The selected drive control source is determined primarily by the value in P.000. However, if P.000 = rE,
then the REM/LOC input may toggle the control source between the local keypad and the terminal strip.
See P.007 (Terminal Strip Digital Inputs Configure).
Depending on the control source selected, the AUTO/MAN key can be used to switch between speed
reference sources as shown in the following table.
Control Source (P.000)
AUTO/MAN Status
Speed Reference Source
Local keypad/display
AUTO selected
Terminal strip
(P.000=LOCL)
MAN selected
Local keypad/display or OIM
Terminal strip remote inputs
AUTO selected
Terminal strip
(P.000=rE)
MAN selected
Local keypad/display or OIM
Option port (P.000=OP)
AUTO selected
Network
MAN selected
Local keypad/display or OIM
Serial port (P.000=SErL)
AUTO selected
Terminal strip
MAN selected
Local keypad/display or OIM
Содержание GV3000SE
Страница 2: ......
Страница 4: ......
Страница 5: ...GV3000 SE Power Units Instruction Manual User Manual 49 1327e 11...
Страница 6: ......
Страница 8: ......
Страница 14: ...2 DESCRIPTION 2 4 GV3000 SE 49 1327 e PE Figure 2 2b Typical System Block Diagram Type GV3000 SE AC024 and 030...
Страница 77: ......
Страница 80: ......
Страница 86: ...2 2 GV3000 SE 49 1329 e...
Страница 94: ...3 8 GV3000 SE 49 1329 e...
Страница 134: ...4 40 GV3000 SE 49 1329 e...
Страница 188: ...7 10 GV3000 SE 49 1329 e...
Страница 196: ...8 8 GV3000 SE 49 1329 e...
Страница 197: ......