3 - INSTALLATION
3-8
GV3000/SE
49'1327 e
Digital Outputs
(see wiring diagram for Remote Terminal Block)
Terminals
Connected function
J1:
28,29
30,31
IET / Controller Running Relay
Digital output with two voltage free contacts at one relay, configurable through P.013
for status indication.
- P.013: 0 = State of active faults (IET)
1 = State of Controller Running (0.5 s delay after start)
2 = State of Controller Running (not delayed)
3 = State of Network Communication ACTIVE
4 = Relay is energized when all start permissive conditions are met.
5 = Relay is energized when one or more alarms are active.
- Contacts rated for max. load of
2 A at 30 VDC or 60 W at L/R = 7 ms, and
2 A at 250 VAC, or 500 VA at cos
ϕ
= 0.4.
- Contacts rated for min. load of 10 mA at 5 VDC.
NC Normally Closed Contact
NO Normally Open Contact
Analog Speed Reference Input
(see wiring diagram)
Terminals
Connected function
J1:
12
13
14
15
+10 VDC Supply, isolated, stabilized, max. 2.7 mA
+15 VDC Supply, isolated, after 1.8 kohm, for Types AC003 - 030 and 039/044
±
10 V
Analog Voltage Speed Reference Input, Impedance 50 kohm
±
20 mA Analog Current Speed Reference Input, Impedance 250 ohm
Common, isolated, for Voltage / Current Input
For Voltage Speed Reference Input: Jumper J4 in upper position (V IN, Default),
Current Speed Reference Input: Jumper J4 in lower position (C IN)
Refer to : P.009 Terminal Strip Analog Input Offset (e.g. for 4 to 20 mA)
P.010 Terminal Strip Analog Input Gain
P.011 Terminal Strip Analog Input Configure
Analog Output
(see wiring diagram for Remote Terminal Block)
Terminals
J1:
Connected function
Note: P.012 -Terminal Strip Analog Output Source
10
Analog output
J17
11
Regulator Common
Jumper J17 setting for type of signal output:
•
voltage (0 - 10 V)
in position V OUT,
V OUT
!
!
0-20mA
!
max. 4 mA, Impedance 2.5 kohm
!
!
!
•
or current (0 or 4 - 20 mA) in position C OUT
C OUT
!
!
4-20mA
!
On types 038/043 and 058-360 the current range
0 - 20 mA or 4 - 20 mA can be selected with the two
jumpers near the relay.
NOTE
: The Analog output for
current signal
is a sink
type and requires an externally mounted
isolated power supply
(max. 12V, min
Σ
R
receiver
x 20 mA).
J1
11
10
Current Output
Load
P/S
+
-
=<500 ohm
Содержание GV3000SE
Страница 2: ......
Страница 4: ......
Страница 5: ...GV3000 SE Power Units Instruction Manual User Manual 49 1327e 11...
Страница 6: ......
Страница 8: ......
Страница 14: ...2 DESCRIPTION 2 4 GV3000 SE 49 1327 e PE Figure 2 2b Typical System Block Diagram Type GV3000 SE AC024 and 030...