![Reliance electric GV3000SE Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/reliance-electric/gv3000se/gv3000se_instruction-manual_1436345009.webp)
1 - INTRODUCTION
49'1327 e
GV3000/SE
1-1
This instruction manual provides a functional description of the Power Units for the PWM-Converters
Type GV3000 with circuit diagram and Specifications (Chapter 2), Installation Guidelines (Chapter 3),
general trouble shooting suggestions with spare parts lists (Chapter 4) and Accessories (Chapter 5).
Appendix A contains guidelines for installation to meet CE-Conformity and EMC Directive
.
Appendix B describes the frequency converters in NEMA design type GV3000U-AC002 to 032
manufactured in USA, which are all UL, cUL and CE approved.
For Start-Up instructions please refer to the regulator manual.
Safety Instructions
DANGER, WARNING, and CAUTION point out potential trouble areas.
A
DANGER
alerts a person that high voltage is present which could result in severe bodily injury or
loss of life.
A
WARNING
alerts a person to potential bodily injury if procedures are not followed.
A
CAUTION
alerts a person that, if procedures are not followed, damage to, or destruction of
equipment could result.
DANGER
:
Before installing and/or operating this device, this manual must be understood by the
qualified electrical maintenance person who is familiar with this type of equipment and
the hazards involved. Failure to observe this precaution could result in bodily injury.
WARNING
:
Earth fault detection devices must not be used on this converter as the sole protection
measure against unintentional touching.
The DC-component in the earth fault current may inhibit the correct function of the fault
detector.
CAUTION
:
Electronic converters cause disturbances to the supply network. The basic version of
this converter does not include any harmonic filters and may not fulfill the limits of the
national recommendations. The harmonic voltage disturbances produced by the
converter are dependent on the supply network impedance.
Machinery Directive
CAUTION
:
This inverter device is a component intended for implementation in machines or
systems for the capital goods industry.
The start-up of the inverter in the European market is not permitted until it has been
confirmed that the machine into which the inverters are built is in conformance with the
regulations of the Council Directive Machinery 98/37/EWG.
WARNING
:
The built-in Stop function (control input at terminal 23 or 20) must not be used as an
emergency stop circuit. To inhibit uncontrolled machine operation in case of the
malfunction of the drive, the user must provide an external emergency stop circuit,
which ensures disconnection of the power source from the motor.
This circuit must be hardwired with electro-mechanic components and shall not depend
on electronic logic or software
.
The stopping device (e.g. mushroom head pushbutton
with lock) must be accessible to the operator.
Failure to observe this precaution could result in bodily injury or loss of life.
Содержание GV3000SE
Страница 2: ......
Страница 4: ......
Страница 5: ...GV3000 SE Power Units Instruction Manual User Manual 49 1327e 11...
Страница 6: ......
Страница 8: ......
Страница 14: ...2 DESCRIPTION 2 4 GV3000 SE 49 1327 e PE Figure 2 2b Typical System Block Diagram Type GV3000 SE AC024 and 030...
Страница 77: ......
Страница 80: ......
Страница 86: ...2 2 GV3000 SE 49 1329 e...
Страница 94: ...3 8 GV3000 SE 49 1329 e...
Страница 134: ...4 40 GV3000 SE 49 1329 e...
Страница 188: ...7 10 GV3000 SE 49 1329 e...
Страница 196: ...8 8 GV3000 SE 49 1329 e...
Страница 197: ......