THERMOJET
®
G3000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740122
Rev
14
Date
JUNE 2020
Page
46
of
104
System Shutdown
ThermoJet Oil Purifiers are equipped with a timing relay which delays cessation of oil flow for 2 minutes after
the power selector switch has been transferred from the ON to the OFF position. The purpose of this delay is
to allow sufficient time for the oil heater to “cool down.” During this cooling interval the oil heater is inoperable
and the oil temperature will decrease. At the end of the 2 minute delay the motor will stop running and the
pump will cease to operated, and the oil pressure will falls to zero.
To shut down the system,1) turn the selector switch form the ON to the OFF position, 2) allow the system to
operate until the motor turns off, 3) turn the main disconnect switch from the ON to the OFF position.
If the unit is turned OFF for system maintenance, see the section of this manual titled
ROUTINE
MAINTENANCE.
. If the unit is being decommissioned see the section of this manual titled
REMOVAL FROM
USE, DISPOSAL AND TRANSPORT
NOTICE:
For EMERGENCY SHUT DOWN switch the main
circuit breaker handle to OFF position.
3) Once system shuts down and
pressure falls to zero, Turn Main
Disconnect Switch to OFF Position
2) Heater ceases to operate. Heater
ON pilot light remains OFF as Oil
circulates to cool down. After 2 minutes
the system will automatically turn OFF
1) Turn ON-OFF Selector
Switch to OFF position