Wait a maximum of 2 minutes for the oil pump to establish oil flow and pressurize the inlet system. As oil
flows into the pump, system pressure will build and be indicated on the filter inlet and filter discharge
pressure gauges located above door. If pressure does not build and no oil is flowing, trace the inlet piping for
blockages such as a closed valve. If the oil path is free from obstructions, manually prime the pump and the
inlet piping. Ensure that the suction line distance is within the allowable limit as mentioned in
INSTALLATION Section of this manual
NOTICE:
Wear appropriate personal protective gear.
When cleaning oil spills consult with your
lubricating oil supplier and the lubricating oil MSDS
documentation regarding safe guards and
Personal Protective Equipment (PPE)
requirements
Observe pressure gauges to verify
that oil is flowing into the ThermoJet
Oil Purifier.