![RelaDyne THERMOJET G3000E Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/reladyne/thermojet-g3000e-series/thermojet-g3000e-series_installation-and-operating-manual_1435630044.webp)
THERMOJET
®
G3000E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740122
Rev
14
Date
JUNE 2020
Page
44
of
104
The daily operation of the ThermoJet system for the process operator has been reduced to monitoring and
daily checks of the ThermoJet oil Purifier to emergency procedures in the event of a major malfunction.
Except for emergencies, routine adjustment of the unit is not required. Any change in the Inlet Pump
Discharge pressure, Filter Discharge pressure or the System Discharge pressure from the initial set points is
an indication that some operational variable has changed. Care should be taken before making adjustments
that might offset the failure symptoms and lead to more serious problems before detection and corrections
can be made.
Keeping system adjustments to a minimum is intended to make the systems more reliable and to insure
proper operation. It is not meant to discourage the natural troubleshooting initiative of the process technician.
Operators should be familiar with the operating instruction of this machine, knowing how to read gauge values
and alarm settings before attempting these procedures.
NOTICE:
Wear appropriate personal protective gear when
collecting oil samples.
In case of oil spillage, the user or other
responsible body must ensure appropriate
cleanup and decontamination is carried out.
Reference CLEANING AND DECONTAMINATION in
the ROUTINE MAINTENANCE section of this
manual.
When collecting oil from the sample valve, the
oil will be hot and under pressure.
WARNING