background image

            

 

 

 

Rev. 3F Aug 2020 

 

 

 

P/N 77740213 

Page  

7

 

 
 

Start-Up Procedures 

 

Once the mist reclassifiers, mist supply and drain tubing, and the air supply line have been installed and connected, system can 
be started by following these steps: 

 

1.  Fill the reservoir to the fill mark.  

DO NOT OVERFILL!

  The oil fill port is located on the left side of the reservoir.  A supply of 

ISO 68 grade lubricant is included with the LubriMate

®

.  Although this grade of oil will suit the lubrication requirements for the 

majority of all applications, a check should be made to insure suitability for the equipment being serviced.  If your model is 
equipped with an oil heater, energize the heater. Check thermostat so that the oil temperature operates at approximately 
110F. 

2.  Make sure the air stripper valve is closed by turning clockwise. 
3.  Turn on the air supply connected to the inlet air pressure regulator and adjust the air pressure regulator knob clockwise until 

the mist pressure gauge reads 20 inches (500mm) of H

2

O.  At this point oil mist is being produced and flowing to the 

bearings.  

THE SUPPLY AIR FLOW SHOULD NOT BE CHANGED FOR THIS PARTICULAR SET-UP FROM THIS POINT 

FORWARD! 

 The oil mist output is now established by the airflow through the Vortex Mist Generator. 

4.  Open the air stripper control valve by turning counter-clockwise until the return mist gauge reads -0.10 to -0.15 inches of H

2

(vacuum) and the oil mist venting from under the return filter cap is no longer visible.  The mist supply pressure will increase 
to approximately 30 to 50 inches of H

2

O.  This increase in mist supply pressure is derived from the coalesced oil being 

injected back into the oil reservoir.  

DO NOT ATTEMPT TO RE-ADJUST THE MIST PRESSURE BACK TO 20” H

2

O.

  

 
 

             

 

 

 

 

 

 
 
 
 

 
 
 
 
 
 

 
System Operation and Adjustment

 

As the system operates over time, the stripping filter element becomes saturated with oil.  This is normal and expected.  However 
the resulting increased pressure drop across the filter may cause a portion of the returning mist to bypass the filter and be vented 
from under the stripper filter cap.  This occurs when the return pressure starts to increase to a slight positive pressure.  To 
remedy this situation, open the air stripper control valve slightly by turning counter-clockwise until only clean air is vented and the 
filter element return pressure again reads -0.10 to -0.15 inches of H

2

O (vacuum).  Several adjustments may be necessary as the 

filter element becomes saturated but a steady state condition will be reached and further adjustment will not be necessary. 
 
As adjustments to the air stripper control valve are made, the mist supply pressure will increase.  Do not adjust the air pressure 
regulator in an effort to return the supply mist pressure to 20 inches of H

2

O.  

THE PROPER MIST SUPPLY VOLUME IS 

ESTABLISHED WHEN THE AIR STRIPPER CONTROL VALVE IS IN THE CLOSED POSITION DURING STEP 4 OF THE 
START-UP PROCEDURE.

  Once the filter element is saturated and final adjustment to the air stripper control valve is made, the 

 

LubriMate Start-Up Sequence 

NOTE:  
At start-up and once oil mist is generated, delivered to the bearings, flows through the housing and returns to the 
LubriMate

®

, excess returned oil mist will vent from under the filter cover and be visible.  This is normal and to strip this 

oil mist from the venting air, follow the procedures in Step 4.  Although oil mist is non-hazardous, one should avoid 
breathing the mist during start-up.

 

Step 2: 

Close air stripper valve 
 

Step 4C: 

Mist supply pressure gauge 
reads 30 to 55 inches of H

2

Step 1: 

Fill reservoir

 

Step 3A: 

Turn on air supply  

Step 4A: 

Open air stripper valve 

Step 4B:  

Adjust air stripper valve until return mist pressure 
gauge reads -0.10 to -0.15 inches of H

2

O (vacuum) 

Step 3B: 

Set mist supply pressure to 
20 inches of H

2

O

 

Содержание LUBRIMATE

Страница 1: ...NO SERIAL NO LubriMist MIST PRESSURE SWITCH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication...

Страница 2: ...gn with coalescing filter eliminates stray mist from venting at the unit thus test stands remain clean and free of oil mist This publication provides instruction and information on the set up and oper...

Страница 3: ...into the bearing housing A drain tube connects the bearing housing drain to any of five return ports located on the LubriMate The air stripper separates the remaining oil from the returned oil mist T...

Страница 4: ...to the inlet air pressure regulator filter 1 8 NPT located at the left side of the unit The inlet air supply should be capable of delivering 4 SCFM at 55 PSIG This is the minimum required air pressure...

Страница 5: ...ation For gear boxes and sleeve bearings with oil level the purge oil mist method is to be used With purge mist the air space above the oil level is filled with oil mist The resulting purge keeps outs...

Страница 6: ...ents is maintained by the splash or recirculation of the oil from the oil reservoir The purge mist itself does not provide the lubrication rather it fills and flows through the volume space above the...

Страница 7: ...istent Viscosity Grade Minimum Operating Temperature ISO 32 32 F 0 C ISO 46 40 F 4 4 C ISO 68 50 F 9 9 C ISO 100 60 F 15 6 C ISO 150 70 F 21 0 C ISO 150 Not Recommended Maintaining Minimum Air Flow to...

Страница 8: ...over time the stripping filter element becomes saturated with oil This is normal and expected However the resulting increased pressure drop across the filter may cause a portion of the returning mist...

Страница 9: ...a leak or loose connection in the supply tubing a missing application fitting or a broken line 5 2 High mist pressure may indicate plugged application fitting or a restricted bearing housing vent or d...

Страница 10: ...CH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication Systems Company FULL ADD OIL LEVEL 131 2 1...

Страница 11: ...ches of H2O 2 77 700 744 Return Pressure Gauge 3 77 700 743 Air Stripping Coalescing Filter Element 4 77 700 742 Bulls Eye Sight Glass 5 LS 02 05 120 Oil Suction Screen 6 77 600 807 Air Filter Pressur...

Страница 12: ...ESURE SWITCH Oil HEATER 120 VAC 250 Watt ALUMINUM PORT TEFLON COATED POLYIMIDE DIAPHRAGM ADJ RANGE 7 H20 DECR TO 100 H20 INCR SPST CONTACT RATING 11 AMP 1 2 HP AT 125 OR 250 VAC 5 AMP RESISTIVE 3 AMP...

Страница 13: ...Rev 3F Aug 2020 P N 77740213 Page 12 Notes and Records...

Отзывы: