The unit includes corrosion resistant  aluminum reservoir having a 1 1/2-gallon charge capacity.  The Vortex oil mist generating 
technology and a highly efficient oil stripping system supplies and reapplies a continuous clean lubricant to bearings.   Other 
standard features include an oil level sight glass, oil temperature gauge, mist pressure gauge, fill and drain ports, relief valve, and 
outlet and return connections for bearing hook-ups.  Inlet air controls include an integral air filter/pressure regulator. 

Optional features include an oil heater and low mist pressure switch. Fittings and hardware sufficient for lubrication  of up to 5 
lubrication points may also be included when ordering. See the LubriMate model code chart for ordering information. 

 

Lubricant is supplied to the serviced equipment bearing housings from any of five outlet connections located on the top of the 
reservoir.  The lubricant/air mixture is conveyed through tubing, metered by an application fitting, and then introduced into  the 
bearing housing.  A drain tube connects the bearing housing drain to any of five return ports located on the LubriMate

®

.  The air 

stripper separates the remaining oil from the returned oil mist.  This coalesced oil is combined with the liquid oil from the bearing 
housing and returned to the oil reservoir.  The supply and return pressure gauges provide a visual verification that proper system 
operation is being maintained. 

When included the LubriMate

®

 comes complete with the following installation accessories.  Check to insure all items are identified 

before beginning installation and operation. 

    

Quantity 

Part Number 

Description 

77-700-725 

LubriMate

®

 Lubricator Unit 

77-800-501 

Mist Reclassifier, Rated 0.09 SCFM @ 20” H2O 

77-800-502 

Mist Reclassifier, Rated 0.18 SCFM @ 20” H2O 

77-800-503 

Mist Reclassifier, Rated 0.30 SCFM @ 20” H2O 

77-700-750 

Supply Tube Fitting Connector, 1/4”T x1/4”P 

77-600-992 

Supply Tube Fitting Connector, 1/4”T x1/8”P 

77-600-996 

Tube Fitting Plug, 1/4”T 

50 Feet 

77-600-999 

Supply Tubing, 1/4” OD 

10 

77-700-093 

Return Tube Fitting Connector, 3/8”T x1/4”P 

77-700-768 

Tube Fitting Plug, 3/8”T 

50 Feet 

77-700-752 

Return Tubing, 3/8” OD 

2 Gallons 

LSO681 

LubriMist

 Synthetic Oil ISO 68 (one gallon container) 

 

Содержание LUBRIMATE

Страница 1: ...NO SERIAL NO LubriMist MIST PRESSURE SWITCH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication...

Страница 2: ...gn with coalescing filter eliminates stray mist from venting at the unit thus test stands remain clean and free of oil mist This publication provides instruction and information on the set up and oper...

Страница 3: ...into the bearing housing A drain tube connects the bearing housing drain to any of five return ports located on the LubriMate The air stripper separates the remaining oil from the returned oil mist T...

Страница 4: ...to the inlet air pressure regulator filter 1 8 NPT located at the left side of the unit The inlet air supply should be capable of delivering 4 SCFM at 55 PSIG This is the minimum required air pressure...

Страница 5: ...ation For gear boxes and sleeve bearings with oil level the purge oil mist method is to be used With purge mist the air space above the oil level is filled with oil mist The resulting purge keeps outs...

Страница 6: ...ents is maintained by the splash or recirculation of the oil from the oil reservoir The purge mist itself does not provide the lubrication rather it fills and flows through the volume space above the...

Страница 7: ...istent Viscosity Grade Minimum Operating Temperature ISO 32 32 F 0 C ISO 46 40 F 4 4 C ISO 68 50 F 9 9 C ISO 100 60 F 15 6 C ISO 150 70 F 21 0 C ISO 150 Not Recommended Maintaining Minimum Air Flow to...

Страница 8: ...over time the stripping filter element becomes saturated with oil This is normal and expected However the resulting increased pressure drop across the filter may cause a portion of the returning mist...

Страница 9: ...a leak or loose connection in the supply tubing a missing application fitting or a broken line 5 2 High mist pressure may indicate plugged application fitting or a restricted bearing housing vent or d...

Страница 10: ...CH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication Systems Company FULL ADD OIL LEVEL 131 2 1...

Страница 11: ...ches of H2O 2 77 700 744 Return Pressure Gauge 3 77 700 743 Air Stripping Coalescing Filter Element 4 77 700 742 Bulls Eye Sight Glass 5 LS 02 05 120 Oil Suction Screen 6 77 600 807 Air Filter Pressur...

Страница 12: ...ESURE SWITCH Oil HEATER 120 VAC 250 Watt ALUMINUM PORT TEFLON COATED POLYIMIDE DIAPHRAGM ADJ RANGE 7 H20 DECR TO 100 H20 INCR SPST CONTACT RATING 11 AMP 1 2 HP AT 125 OR 250 VAC 5 AMP RESISTIVE 3 AMP...

Страница 13: ...Rev 3F Aug 2020 P N 77740213 Page 12 Notes and Records...

Отзывы: