background image

            

 

 

 

Rev. 3F Aug 2020 

 

 

 

P/N 77740213 

Page  

4

 

Pure Mist to Rolling Element Bearings

 

Lubrication is achieved by insuring that the oil mist flows through the bearing prior to being vented from the drain connection or 

through the shaft end seals.  The proper path for the mist is from one side of the bearing to the other, flowing parallel to the 

spindle shaft.  Application fittings should be installed in the upper hemisphere of the bearing housing and not on the LubriMate

®

.  

Flow from the reclassifier should be directed downward from the horizontal.  The mist should be required to pass through no more 

than two rows of rolling elements (double row ball bearing).  To contain the oil mist and avoid venting into the surrounding area, 

positive seals around shafts should be provided.  Anti-friction bearings supporting either horizontal or vertical shafts may be 

lubricated with pure oil mist.  

 

Purge Mist to Gear Boxes and Plain/Sleeve Bearings 

The LubriMate

®

 Unit may also be used to purge machinery gearboxes and bearing housings having plain or sleeve type bearings.  

Because these type of machinery elements generate a great deal of frictional heat, the pure oil mist with no sump oil as described 
above is not suitable unless special designed considerations are provided by the original equipment manufacturer.  The design 
and application of oil mist to machinery elements, other than anti-friction rolling element type bearings, without the original 
recommended oil level is not in the scope of this publication.  For gear boxes and sleeve bearings with oil level the purge oil mist 
method is to be used. 
 
With purge mist, the air space above the oil level is filled with oil mist.  The resulting purge keeps outside contamination from 
entering the bearing housing during cool down should the machinery be turned on and off.  The LubriMate

®

  also continuously 

deposits a thin film of clean lubricant on all equipment internals, giving them additional protection during equipment shutdown, 
start-up, and operation.  Purge application requires the use of LubriMist

®

  purge mist application.  LubriMist

®

  purge mist 

accessories are available for purchase from manufacturer. 
 
The LubriMist

®

 Purge Mist Vent/Fill Assembly should be installed directly in the upper hemisphere of the bearing housing above 

the oil level.  When the LubriMist

®

 Purge Mist Vent/Fill Assemblies is used, install a size 501 reclassifier directly into the mist inlet 

of the assembly.  Flow should move downward from horizontal.  

 
 
 

 
The LubriMist

®

 oil level site assembly is designed to maintain proper oil level in the bearing housing.  Also, with the installation of 

the pressure balance line, the internal housing pressure is maintained at atmospheric pressure so that oil level in the housing is 
not affected. 

 

 

IMPORTANT 

When connecting a bearing 
housing where an operating 
oil level is to be maintained, 
insure that the internal 
housing pressure does not 
adversely affect the oil level. 

 

Purge mist, vent/fill 

assembly

 

77-800-501 
Reclassifier 

Supply tubing; 

¼” OD

 

Drain tubing; 

3/8“ OD

 

Oil level site 

assembly with 

pressure balance 

line

 

Provide positive shaft seals

 

Drain tubing, 3/8“ OD

 

Mist reclassifiers

 

Supply tubing; ¼” OD

 

Lubricating Anti-Friction Ball Bearings

 

Содержание LUBRIMATE

Страница 1: ...NO SERIAL NO LubriMist MIST PRESSURE SWITCH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication...

Страница 2: ...gn with coalescing filter eliminates stray mist from venting at the unit thus test stands remain clean and free of oil mist This publication provides instruction and information on the set up and oper...

Страница 3: ...into the bearing housing A drain tube connects the bearing housing drain to any of five return ports located on the LubriMate The air stripper separates the remaining oil from the returned oil mist T...

Страница 4: ...to the inlet air pressure regulator filter 1 8 NPT located at the left side of the unit The inlet air supply should be capable of delivering 4 SCFM at 55 PSIG This is the minimum required air pressure...

Страница 5: ...ation For gear boxes and sleeve bearings with oil level the purge oil mist method is to be used With purge mist the air space above the oil level is filled with oil mist The resulting purge keeps outs...

Страница 6: ...ents is maintained by the splash or recirculation of the oil from the oil reservoir The purge mist itself does not provide the lubrication rather it fills and flows through the volume space above the...

Страница 7: ...istent Viscosity Grade Minimum Operating Temperature ISO 32 32 F 0 C ISO 46 40 F 4 4 C ISO 68 50 F 9 9 C ISO 100 60 F 15 6 C ISO 150 70 F 21 0 C ISO 150 Not Recommended Maintaining Minimum Air Flow to...

Страница 8: ...over time the stripping filter element becomes saturated with oil This is normal and expected However the resulting increased pressure drop across the filter may cause a portion of the returning mist...

Страница 9: ...a leak or loose connection in the supply tubing a missing application fitting or a broken line 5 2 High mist pressure may indicate plugged application fitting or a restricted bearing housing vent or d...

Страница 10: ...CH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication Systems Company FULL ADD OIL LEVEL 131 2 1...

Страница 11: ...ches of H2O 2 77 700 744 Return Pressure Gauge 3 77 700 743 Air Stripping Coalescing Filter Element 4 77 700 742 Bulls Eye Sight Glass 5 LS 02 05 120 Oil Suction Screen 6 77 600 807 Air Filter Pressur...

Страница 12: ...ESURE SWITCH Oil HEATER 120 VAC 250 Watt ALUMINUM PORT TEFLON COATED POLYIMIDE DIAPHRAGM ADJ RANGE 7 H20 DECR TO 100 H20 INCR SPST CONTACT RATING 11 AMP 1 2 HP AT 125 OR 250 VAC 5 AMP RESISTIVE 3 AMP...

Страница 13: ...Rev 3F Aug 2020 P N 77740213 Page 12 Notes and Records...

Отзывы: