background image

            

 

 

 

Rev. 3F Aug 2020 

 

 

 

P/N 77740213 

Page  

1

 

LubriMate

®

 Lubrication System

 

 

INSTALLATION AND OPERATION MANUAL - P/N 77 740 213 
 

 

Model Code 

 

 

 

WLM - 

 

 

 

OPTION DESCRIPTION 

 

NO OIL HEATER w/ THERMOSTAT 

OIL HEATER w/ THERMOSTAT 
INCLUDED 

 

 

NO LOW MIST PRSSURE SWITCH 

LOW MIST PRSSURE SWITCH 
INCLUDED 

NO ACCESSORY PACK 

ACCESSORY PACK INCLUDED 

.Standard Model is WLM-XXX 

 

Introduction 

The LubriMate

®

 Oil Mist Lubrication System provides oil mist lubrication to rotating machinery and equipment.  Its design allows 

for easy installation and use during equipment operation.  The LubriMate

®

 Oil Mist Lubrication System is designed for application 

to bearings, gearboxes, chains, and sliding surfaces in various industrial machinery and equipment that will be lubricated with oil 
mist.  The unit requires a clean and dry compressed air supply to generate the oil mist. Units equipped with oil heaters require a 
separate circuit protected electrical power supply. The optional low mist pressure switch has a SPDT contact for wiring to the 
users alarm circuit or enunciator. The unique design with coalescing filter eliminates stray mist from venting at the unit thus test 
stands remain clean and free of oil mist.  This publication provides instruction and information on the set-up and operation of the 
unit. 

 

Description

 

The LubriMate

®

  is a recirculating oil mist system; it produces and delivers the oil mist plus it captures returned liquid oil and 

coalesces returned oil mist for continuous reuse and recirculation.  The air venting from the unit is essentially hydrocarbon free.  
As with other LubriMist

®

 

products, the equipment is based upon proven oil mist lubrication technology and utilizes manufacturer’s 

proprietary Vortex mist generation technology to deliver superior reliability and performance. 

 

MODEL NO.

SERIAL NO.

LubriMist

 MIST PRESSURE SWITCH RATING

OIL HEATER

VOLTS

WATTS

                              P.O. BOX 19294
                   HOUSTON,TEXAS 77224-9294
713/464-6266 · FAX 713/464-9871 · 1-800-800-LUBE
                                www.lsc.com

THE RIGHT CHOICE

Lubrication
Systems
Company

FULL

ADD

O

IL

 L

E

VE

L

 

 

Return Oil Connections 

 

Supply Air Connection 

 

Air Stripper 

Assembly 

 

Supply Mist Connections 

 

Optional Oil Heater 

 

Optional Low Mist 
Pressure Switch 

 

Mist Pressure 
Gauge 

 

Aluminum Reservoir with Oil Level 
Gauge and Oil Temperature 

 

 

Vortex Mist Generating Head 

 

Fill Port 

 

Return Pressure Gauge 

 

Relief Valve 

 

Содержание LUBRIMATE

Страница 1: ...NO SERIAL NO LubriMist MIST PRESSURE SWITCH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication...

Страница 2: ...gn with coalescing filter eliminates stray mist from venting at the unit thus test stands remain clean and free of oil mist This publication provides instruction and information on the set up and oper...

Страница 3: ...into the bearing housing A drain tube connects the bearing housing drain to any of five return ports located on the LubriMate The air stripper separates the remaining oil from the returned oil mist T...

Страница 4: ...to the inlet air pressure regulator filter 1 8 NPT located at the left side of the unit The inlet air supply should be capable of delivering 4 SCFM at 55 PSIG This is the minimum required air pressure...

Страница 5: ...ation For gear boxes and sleeve bearings with oil level the purge oil mist method is to be used With purge mist the air space above the oil level is filled with oil mist The resulting purge keeps outs...

Страница 6: ...ents is maintained by the splash or recirculation of the oil from the oil reservoir The purge mist itself does not provide the lubrication rather it fills and flows through the volume space above the...

Страница 7: ...istent Viscosity Grade Minimum Operating Temperature ISO 32 32 F 0 C ISO 46 40 F 4 4 C ISO 68 50 F 9 9 C ISO 100 60 F 15 6 C ISO 150 70 F 21 0 C ISO 150 Not Recommended Maintaining Minimum Air Flow to...

Страница 8: ...over time the stripping filter element becomes saturated with oil This is normal and expected However the resulting increased pressure drop across the filter may cause a portion of the returning mist...

Страница 9: ...a leak or loose connection in the supply tubing a missing application fitting or a broken line 5 2 High mist pressure may indicate plugged application fitting or a restricted bearing housing vent or d...

Страница 10: ...CH RATING OIL HEATER VOLTS WATTS P O BOX 19294 HOUSTON TEXAS 77224 9294 713 464 6266 FAX 713 464 9871 1 800 800 LUBE www lsc com THE RIGHT CHOICE Lubrication Systems Company FULL ADD OIL LEVEL 131 2 1...

Страница 11: ...ches of H2O 2 77 700 744 Return Pressure Gauge 3 77 700 743 Air Stripping Coalescing Filter Element 4 77 700 742 Bulls Eye Sight Glass 5 LS 02 05 120 Oil Suction Screen 6 77 600 807 Air Filter Pressur...

Страница 12: ...ESURE SWITCH Oil HEATER 120 VAC 250 Watt ALUMINUM PORT TEFLON COATED POLYIMIDE DIAPHRAGM ADJ RANGE 7 H20 DECR TO 100 H20 INCR SPST CONTACT RATING 11 AMP 1 2 HP AT 125 OR 250 VAC 5 AMP RESISTIVE 3 AMP...

Страница 13: ...Rev 3F Aug 2020 P N 77740213 Page 12 Notes and Records...