Eliminating malfunctions
40
Eliminating malfunctions
The malfunctions and causes of malfunctions described in this section can only serve
as a starting point for your checks. Malfunctions are related to the type of use and the
respective operating situation. For this reason always incorporate all components of
the entire system in your fault finding and elimination process. Pertinent information
can be found in the overall documentation for your system.
Detecting malfunctions
The coupling must show a low-noise and vibration-free running behaviour in all
phases of operation. Anomalies in the operating behaviour are always indications of
the presence of a malfunction.
Make sure that the cause of the malfunction is located and immediately eliminated
by qualified, specialist personnel.
Table of malfunctions
Malfunction
Cause
Remedy
Sudden change in the
noise level
Sudden occurrence of
vibrations
The alignment of the
coupling has been
changed.
Decommission the system.
Identify the reason for this
change, for example
loosened foundation bolts.
Make sure that the alignment
of the coupling is corrected
properly.
The flexible elements
are worn.
Decommission the system.
Information regarding this can
be found from page 48.
Make sure that the flexible
elements are replaced
properly.
Make sure that the coupling
is mounted and aligned
properly.
Information regarding this can
be found from page 25.