08 Advanced configuration
Water Sensor offers a wide variety of advanced configuration settings.
Below parameters can be accessed from main controllers configuration
interface.
Parameter No. 14 Enable/Disable BASIC SET command
Water Sensor can send BASIC SET command to nodes associated
with group 2.
0 – Disable.
1 – Enable.
Default setting: 0
Parameter size: 1 [byte]
Parameter No. 15 Value of the BASIC SET
Water sensor can reverse its value of BASIC SET when flooding is
triggered.
0 – Send BASIC SET VALUE = 255 to nodes associated with group 2
when flooding alarm is triggered.
Send BASIC SET VALUE = 0 to nodes associated with group 2 when
flooding alarm is canceled.
1 – Send BASIC SET VALUE = 0 to nodes associated with group 2 when
flooding alarm is triggered.
Send BASIC SET VALUE = 255 to nodes associated with group 2
when flooding alarm is canceled.w
Default setting: 0
Parameter size: 1 [byte]
Parameter No. 17 Set resend flooding alarm interval (minute)
Available settings: 1 – 240
Default setting: 5
Parameter size: 1 [byte]