01.02 Spezifikation
Power supply:
ER14250 3.6 V Battery
Storage environment:
–20 °C – +60 °C
0 % – 90 % r.H.
Operational temperature: ±0 °C – +40 °C
Radio protocol:
Z-Wave plus
Radio frequency:
868.42MHz (EU version)
869 MHz (RU version)
Range:
More than 100 m outdoors
up to 30 m indoors (depending on building
materials)
Dimensions:
Main body: 65 mm x 65 mm x 22 mm
Cable lenght extension probe: 1 m
Working current:
About 40 mA
Standby current:
About 24 μA
Transmitted power:
–7.08 dBm ERP
02 Activation
1. Turn the cover counter-clockwise and open it.
Open with coin
Содержание RE.GUARD