1. Introduction
CSE SOL G SRS1 T-K Solar Pump Station is fitted with a solar pump of the latest generation that
permits flow control either internally by selecting a suitable mode or externally through PWM signal.
The complicated setting of the right flow rate is not needed when the PWM signal is used, the pump
station keeps adjusting it automatically, depending on the actual solar radiation. This means that the
solar thermal system always works with the maximum possible efficiency.
Thanks to a direct connection of a gas boiler or another switched heat source through a special
connector, a long power cable for the pump station and a cable ready to connect to a solar sensor,
the installation is easy and fast, no qualified electrician is needed.
2. Pump Station Description
Main Features
Application
This solar pump station contains all components necessary for current and
efficient operation incl. complete electrical wiring. It is necessary to connect
only the collector temperature sensor and a switched heat source through
the special connector (see the following text).
This solar pump station contains all components necessary for current and
efficient operation incl. complete electrical wiring. It is necessary to connect
only the collector temperature sensor and a switched heat source through
the special connector (see the following text).
Description
The pump station consist of a UPM3 Hybrid 25-70 pump, SRS1 T controller,
check and safety valves, 2 ball valves, pressure gauge, thermometer, el. wiring,
insulation and installation kit.
The pump station further involves:
● connection point for an expansion vessel,
● safety valve outlet, incl. extension piping terminating under the pump station
for easier connection,
● ball valves for filling, draining and topping up a solar thermal system,
● ball valves for filling, draining and topping up a solar thermal system,
● solar temperature sensor (2m cable, silicone insulation),
● cable with a special connector to connect a gas boiler or another switched
heat source (4m cable),
● 230V power cable w. el. plug (3m cable, PVC insulation).
Installation
on a tank or wall
Working fluid
water-glycol mixture (max. 1:1)
Codes corresponding to connection sizes
Connection
G 3/4“ M
G 1“ M
Flow measurement range
2-12 l/min
8-28 l/min
Code
18971
18966