background image

3. Pump Station Data

Data for CSE SOL G SRS1 T-E Pump Station 

Max. fluid working temperature

110 °C

Max. working pressure

6 bar

Min. system pressure

1.3 with the pump stopped

El. heating element

resistive load max. 3000 W / 230 V (see accessories)

External circulation pump

induction load max. 3000 VA / 230 V

Power supply

230 V, 50 Hz

IP rating

IP20

Ambient temperature

5 - 40 °C

Max. relative humidity

85 % at 25 °C

Overall dimensions

470 x 265 x 120 mm

Total weight

6.8 kg

Min. values of working pressure**

Values of min. working pressure

at the pump suction port  

depending on temperature

0.8 bar at 50 °C
1.2 bar at 90 °C
1.8 bar at 110 °C

** this condition is met for current installations when the initial system pressure is set following the formula (see the Instructions for  

    solar collectors): 

p = 1,3 + 0,1·h [bar] 

where h… is the height from pressure gauge to the middle of collector array [m]

Pump station internal wiring

Temperature Resistance Table for Pt1000 Sensors

°C

0

10

20

30

40

50

60

70

80

90

100

Ω

1000

1039

1077

1116

1155

1194

1232

1270

1308

1347

1385

SRS1 T  

CONTROLLER

SPECIAL CONNECTOR (MALE) 

IN THE PUMP STATION 

TO CONNECT SWITCHED SOURCE

L

 

live

N

 

neutral

RI, R

  

potential-free switching contact

Vi

 

iPWM feedback signal

-

  

GND PWM

V

 

PWM control signal output

S3

 

sensor 3 (after-heating, recirculation)

S2

 

sensor 2 (solar consumer)

S1

 

sensor 1 (collector)

Содержание 18966

Страница 1: ...www regulus eu CSE SOL G SRS1 T K CSE SOL G SRS1T K EN Installation and Operation Manual CSE SOL G SRS1 T K SOLAR PUMP STATION ...

Страница 2: ... the special connector see the following text This solar pump station contains all components necessary for current and efficient operation incl complete electrical wiring It is necessary to connect only the collector temperature sensor and a switched heat source through the special connector see the following text Description The pump station consist of a UPM3 Hybrid 25 70 pump SRS1 T controller ...

Страница 3: ...ature 0 8 bar at 50 C 1 2 bar at 90 C 1 8 bar at 110 C this condition is met for current installations when the initial system pressure is set following the formula see the Instructions for solar collectors p 1 3 0 1 h bar where h is the height from pressure gauge to the middle of collector array m Pump station internal wiring Temperature Resistance Table for Pt1000 Sensors C 0 10 20 30 40 50 60 7...

Страница 4: ... THE UPPER PART OF INSULATION 7 PRESSURE GAUGE 8 EXPANSION VESSEL CONNECTION POINT 3 4 M 9 6 BAR SAFETY VALVE 10 FILLING BALL VALVE 11 SPANNER FOR CONTROL OF BALL VALVE W SIDE OUTLET 12 DRAIN BALL VALVE 13 SRS1 T ELECTRONIC CONTROLLER 14 EL WIRING BOX WITH CONNECTOR TO CONNECT SWITCHED HEAT SOURCE 15 SAFETY VALVE WASTE PIPE Ø22 mm 4 Pump Station Components 1 2 3 4 5 6 7 8 9 10 11 12 15 13 14 Flowm...

Страница 5: ...he flow indicator Turning the lever or the key or pliers a quarter turn to the right closes the ball valve It opens when the lever is turned to the left Before closing opening the ball valve it is necessary to remove the front part of the insulation As a result closing the system is reserved for installation or service technicians only Thus the user cannot simply close the solar circuit and cause ...

Страница 6: ... controlled by potential free contact cable included in pump station supply 3 solar collectors 4 solar pump station 5 pump station for DHW recirculation CSE TVMIX ZV 6 safety kit for HW storage tank 7 solar expansion vessel 8 DHW expansion vessel 9 HC expansion vessel SV cold water TV hot water CV hot water recirculation ÚT central heating KK ball valve ZV check valve AOV automatic air vent valve ...

Страница 7: ...7 1 Overview of Hydraulic Variants 2 4 6 ...

Страница 8: ...by PWM C control signal profile for solar systems WARNING IMPORTANT The pump permits to be controlled also by PWM A signal profile for use in heating systems This mode must not be used for solar thermal systems Using the PWM A pump profile would cause system damage Performance curves Line type Description Constant speed Proportional pressure Constant pressure ...

Страница 9: ...on the current system pressure drop CONTROL MODE DESCRIPTION Constant pressure I The lowest curve of constant pressure II The middle curve of constant pressure III The highest curve of constant pressure AUTOADAPT Automatically controls performance in the range from the highest to the lowest constant pressure curve c INTERNAL CONTROL Constant speed The pump runs at constant speed Pump operating poi...

Страница 10: ...ODE green LED FLASHING INTERNAL 1 Proportional pressure AUTOADAPT 2 Constant pressure AUTOADAPT 3 Proportional pressure I 4 II 5 III 6 Constant pressure I 7 II 8 III 9 Constant speed I 10 II 11 III DISPLAY CONTROL MODE green LED NOT FLASHING EXTERNAL 12 PWM C 13 PWM A I WARNING DO NOT USE THESE MODES 14 II 15 III ...

Страница 11: ...rmance Setting selection To select your desired setting press the button repeatedly until you find the setting you need see the table above If you pass the desired setting you have to go one more round until it appears again The order of modes corresponds to the table Error Display DISPLAY CONTROL MODE Seized pump Too low power supply voltage Electric fault Pump Wiring socket for power supply A an...

Страница 12: ...to the fill and drain ball valves using hoses see Chap 4 and open these valves After filling the solar thermal system close the fill and drain ball valves disconnect the hoses and re open the ball valve above the pump Prior to commissioning the system both the ball valves must be open 2022 We reserve the right to errors changes and improvements without prior notice REGULUS spol s r o E mail sales ...

Отзывы: