3
Putting up your fixture
Step 1: TURN OFF THE POWER at the main fuse/breaker box.
Step 2:
Install the bulb as described in
“Installing the bulb.”
Step 3:
Loosen, but do not remove, the two lens screws and retain
ing clips on the front of the fixture.
Step 4:
Insert the outer edge of the glass lens under the retaining
clips. Make sure that you can read the caution printed on
the front of the lens.
Step 5:
Tighten the two lens screws, making sure that the retaining
clips are tight enough to hold the lens in place.
Step 6:
Loosen the swivel bolt (B) with adjustable wrench. Thread
the coverplate onto the mounting arm of the fixture. Tighten
the locknut to the coverplate (make sure the locknut is on
the outside of the coverplate).
Step 7:
Connect wires as described in
“Wiring your fixture.”
Step 8:
Install coverplate to junction box.
Step 9:
Aim fixture vertically to desired position and tighten swivel
bolt (B) using adjustable wrench. Do not aim fixture 60
degrees or more below horizontal.
Step 10:
Apply weatherproof silicone caulking around coverplate to
provide a watertight seal.
Step 11:
Turn power back on.
Wiring your fixture
Step 1: TURN POWER OFF at main fuse/breaker box.
Step 2:
Connect the black fixture wire to the black supply wire (hot).
Step 3:
Connect the white fixture wire to the white supply wire (neutral).
Step 4:
Connect the green ground wire to a suitable ground.
NOTE:
Be careful to connect the wires correctly. Make sure no bare
strands of wire extend from the wire nut or other approved
wire connectors (not provided).
nstalling the bulb
Step 1:
Screw the bulb securely into socket.
Step 2:
Back the bulb out one or two turns, then screw bulb back in
to ensure proper position in socket.
NOTE: When turned on, bulb will glow dimly at first, building to
full power in 5-7 minutes. When replacing the bulb, you
must always use the same wattage and type of bulb that
was originally supplied with the fixture. Failure to do so
could result in damage to the fixture and bulb. This will
void the warranty. Always turn off or disconnect power
before servicing to reduce risk of electrical shock.
Installing the bulb
Wiring your fixture
Putting up your fixture
SMV80 Series IS. 325-1436.qxd 2/16/04 4:38 PM Page 3