U32SE-5 FPI Direct Vent Gas Insert
15
INSTALLATION
FINAL CHECK
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes:
1)
Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes.
2)
If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.
3)
Check for proper draft.
CAUTION
Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the
responsibility of the manufacturer.
OPTIONAL WALL THERMOSTAT
A wall thermostat may be installed if desired, follow the wiring diagram
below. FPI offers an optional programmable thermostat but any 250-750
millivolt rated non-anticipator type thermostat that is CSA, ULC or UL
approved may be used.
CAUTION
Do not connect the millivolt wall thermostat wires
to the 120V wires.
Thermostat Wire Table
OPTIONAL REMOTE CONTROL
Use the FPI Remote Control Kit approved for this unit. Use of other
systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver
and a wall mounting plate.
1)
Choose a convenient location on the wall to install the receiver and
the receptacle box (protection from extreme heat is very important).
Run wires from the fi replace to that location. Use Thermostat Wire
Table.
2)
Connect the two wires to the gas valve. See wiring diagrams. Optional
wall switch GT/GTM using wire 0.584.907
3)
Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline bat-
teries in the receiver. Install the receiver and its cover in the wall.
Switch the remote receiver to "remote" mode. The remote control is
now ready for operation.
BATTERY INSTALLATION
OPTIONAL PEBBLES / GLASS CRYSTAL INSTALLATION
FOR FIREBOX BASE (AROUND BURNER)
Firebox (Around Burner) Packages
Unit
Glass Crystals
Pebbles
HZ54E / HZ54EPV
6 lbs
2 packages (6 x bags pebbles)
HZ42 / HZ42E / HZ40E
5 lbs
2 packages (6 x bags pebbles)
HZ42ST / HZ42STE / HZ42STEPV 5 lbs
2 package (6 x bags pebbles)
HZ30E
2 lbs
1 package (3 x bags pebbles)
HZI540EB
4 lbs
1.5 packages (4 x bags pebbles)
HZI390E/ HZI390EB
3 lbs
1 package (3 x bags pebbles)
HZI234E
2 lbs
1 package (3 x bags pebbles)
HZO42 / HZO42 (AUS)
3 lbs
1 package (3 x bags pebbles)
P33S / P33SE
3 lbs
1 package (3 x bags pebbles)
1) 4 AA batteries must be installed in the battery pack to operate the burner switch.
2) Install 2 AA batteries per side and connect as shown below.
CAUTION
Do not connect the millivolt
remote control
the 120V wires.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
50 Ft.
16 GA.
32 Ft.
1
8
GA.
20 Ft.
20 GA.
12 Ft.
22 GA.
9 Ft.