U32SE-5 FPI Direct Vent Gas Insert
11
INSTALLATION
VENTING
THE APPLIANCE MUST NOT BE
CONNECTED TO A
CHIMNEY FLUE SERVING A
SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to two
3" (76mm) co-linear aluminium fl ex running the full
length of the chimney. The fl ue length must be a
minimum length of 8 ' (2.44m) and a maximum of 35'
(10.7m). See chart below for minimum distances from
roof. Periodically check that the vent is unrestricted.
Masonry chimneys may take various contours which
the fl exible liner will accommodate. However,
keep
the fl exible liner as straight as possible
, avoid
unnecessary bending.
The Air Intake pipe must be attached to the inlet air
collar of the termination cap.
Part #
Description
948-305
3" Flex - 35 ft.
946-529
Co-linear DV Vertical
Termination
Cap
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work with
gas piping may make the necessary
gas connections
to this appliance.
1)
If the appliance is to be installed into an existing
chimney system, thoroughly clean the masonry
or factory built fi replace.
2)
The appliance is provided with an opening on
the left hand side of the control compartment.
A 3/8" NPT gas supply pipe must be brought
near this inlet hole.
3)
Locate the center point where the vent will pass
through the chimney above the appliance. Move
the appliance into the exact location where it is
to be installed. Ensure that the Insert is level.
12" Mantel
3-1/2"
Mantel
47”
(1194mm)
to ceiling
17"
13"
20“
to floor
2
0
12
6
4
8
10
2
0
12
6
16
4
14
8
18
10
Side View
Top of
Unit
Faceplate
To
p
G
CL
Gas
Inlet
Alternate Approved Caps
46dva-VC Vertical
Termination
Cap
46dva-VCH High Wind Cap
46dva-GK 3" Co-linear Adaptor with fl ashing
In areas of consistently high winds, we recommend
using the Simpson Dura-Vent System (46dva-GK
adapter and 46dva-VCH high-wind cap).
The Air Intake pipe must be attached to the inlet
air collar of the termination cap.
Due to the extreme heat this fi replace emits,
the mantel clearances are critical.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Mantel can be installed anywhere in shaded area
or higher using the above scale.
Note: Ensure the paint that is used on the
mantel and the facing is "heat resistant"
or the paint may discolour.
COMBUSTIBLE MANTEL
CLEARANCES