30
|
Liberty
®
L234-10 Direct Vent Gas Insert
|
30
maintenance
2) Remove the Termination Cap, and shine a
flashlight down the Vent. Remove any bird nests,
or other foreign material.
3) Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints.
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4) Inspect joints to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs. Turn
off the gas valve and allow the unit to cool before
opening door to carefully remove the logs. The pilot
light generates enough heat to burn someone. If for
any reason a log should need replacement, you
must use the proper replacement log. The position
of these logs must be as shown in the diagram
under Log Installation.
NOTE: Improper positioning of logs may create
carbon build-up and will alter the unit’s performance
which is not covered under warranty.
GLASS GASKET
If the glass gasket requires replacement use a
tadpole gasket for the Flush Front Glass (Part #
936-155).
Top view of pilot flame
Top View of pilot flame
Incorrect flame pattern will have small, probably
yellow flames, not coming into proper contact with
the rear of the burner or thermopile.
Never operate the appliance without the
glass properly secured in place or with
the door open.
7) Do not use this appliance if any part has
been under water. Immediately call a qualified
service technician to inspect the appliance
and to replace nay part of the control system
and any gas control which has been under
water.
8) Periodically check the pilot flames. Correct
flame pattern has three strong blue flames: 1
flowing around the thermopile and 1 around
the thermocouple, and 1 flowing across the
front of the burner.
Note: If you have an incorrect flame pattern,
contact your Regency dealer for
further instructions.
6) Each time the appliance is lit, it may cause
condensation and fog the glass. This
condensation and fog is normal and will
disappear in a few minutes as the glass heats
up.
WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE
HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY
AWAY TO AVOID BURNS OR CLOTHING
IGNITION. YOUNG CHILDREN SHOULD
BE CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CAUTION: ANY SAFETY SCREEN OR
GUARD REMOVED FOR SERVICING
AN APPLIANCE MUST BE REPLACED
PRIOR TO OPERATING THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.
MAINTENANCE
INSTRUCTIONS
1) Always turn the gas valve to the off position
before cleaning. For relighting, refer to
lighting instructions. Keep the burner and
control compartment clean by brushing and
vacuuming at least once a year.
When cleaning the logs, use a clean soft
paint brush as the logs are fragile and easily
damaged.
2) Clean (never when unit is hot) appliance,
door and louvers with a damp cloth. Never
use an abrasive cleaner. The finishes on
louvers and doors may be scratched if
abrasives are used to clean them. The
heater is finished in a heat resistant paint
and should only be refinished with heat
resistant paint (not with wall paint). Regency
uses StoveBrite Paint - Metallic Black #6309.
3) Make a periodic check of the burner for
proper position and condition. Visually check
the flame of the burner periodically, making
sure the flames are steady: not lifting or
floating. If there is a problem, call a qualified
service person.
4) The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation
air is not obstructed.
During the annual service call, the burners
should be removed and cleaned from the
burner tray.
5) Keep the area near the appliance clear and
free from combustible materials, gasoline
and other flammable vapours and liquids.
Front Burner Tube
Front Burner Tube
DOOR GLASS
Your Regency insert is supplied with high
temperature, 5 mm Neoceram ceramic glass that
will withstand the highest heat that your unit will
produce. Do not abuse the glass by striking the
surface or by slamming the door shut.
If your glass requires cleaning, we recommend using
an approved glass cleaner available at all authorized
dealers.
Do not use abrasive materials. Do not
clean the glass when hot.
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency dealer only, do not use substitute materials.
Follow our step-by-step instructions for replacement.
Warning: Wear gloves when removing damaged
or broken glass.
Caution: Do not operate appliance with
glass panels removed, cracked or broken.
Replacement of the glass should be done by a
licensed or qualified service person.
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements. These
will appear as rust spots or streaks, and in
extreme cases, holes. These components
should be replaced immediately.
Содержание L234-LP10
Страница 37: ...Liberty L234 10 Direct Vent Gas Insert 37 37 warranty MAIN ASSEMBLY a ...
Страница 38: ...38 Liberty L234 10 Direct Vent Gas Insert 38 parts list 537 924 Low Profile Faceplate ...
Страница 39: ...Liberty L234 10 Direct Vent Gas Insert 39 39 notes ...
Страница 44: ...44 Liberty L234 10 Direct Vent Gas Insert 44 warranty ...
Страница 45: ...Liberty L234 10 Direct Vent Gas Insert 45 45 notes ...
Страница 46: ...46 Liberty L234 10 Direct Vent Gas Insert 46 notes ...
Страница 47: ......