10
|
Liberty
®
L234-10 Direct Vent Gas Insert
|
10
installation
11) Due to high temperatures, the appliance
should be located out of high traffic areas
and away from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperatures,
especially the fireplace glass, and should
stay away to avoid burns or clothing
ignition. Young children should be carefully
supervised when they are in the same
room as the appliance. Clothing or other
flammable material should not be placed
on or near the appliance.
INSTALLATION
CHECKLIST
Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.
The Regency Gas Insert is installed as listed
below.
1) Check all clearances to combustibles. Refer
to the following sections where applicable:
a. Minimum Clearances to Combustibles.
b. Combustible Mantel Clearances
c. Mantel Clearances
2) Make the gas connection. Refer to the "Gas
Connection" section.
3) Install the 3" x 3" or 3" x 2" flue liner to the
sliding connector plate. Refer to the "Flue
Liner Installation" section.
4) Slide the unit half way into the fireplace.
5) Pull the vent connector plate through the
tapered brackets and fasten to the front
plate. Refer to the "Flue Liner Installation"
section.
6) Install 4AA batteries into receiver. Hook
receiver to wire marked receiver, this will
enable operation of the appliance manually
when position in "ON" position.
7) Slide the unit fully into the fireplace.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
8) Test gas pressure, refer to the "Gas Pipe
Pressure Testing" section. Check aeration
system, refer to "Gas Insert Aeration
Systems" section.
9) Install standard and optional features. Refer
to the following sections where applicable:
a. Brick Panels
b. Log Installation
c. Faceplate
d. Optional Hearth Trim
e Remote Control
f. Wall Thermostat
10) Final check. Refer to the "Final Check"
section. Before leaving this unit with the
customer, the installer must ensure that the
appliance is firing correctly. This includes:
a) Clocking the appliance to ensure the
correct firing rate.
b) Adjusting the primary air, if required,
to ensure that the flame does not
carbon. Refer to the "Gas Insert
Aeration System" section.
c) Ensuring that the appliance is venting
correctly.
MATERIALS
REQUIRED
No electrical power supply is required for the gas
control to operate. A 120 Volt AC power cord is
hooked up to the fan. Plug the 3 wire cord into
a suitable receptacle.
Do not cut the ground
terminal off under any circumstances. When
connected with 120 volts, the appliance must
be electrically grounded in accordance with
local codes, current version of the Canadian
Electrical Code CSA C22.1 (in Canada) or in
the absence of local codes, with the National
Electrical Code ANSI/NFPA 70.
MINIMUM FIREPLACE
OPENING
The minimum fireplace opening for the L234 gas
fireplace insert is shown in the following diagrams:
WARNING:
Electrical Grounding
Instructions
This appliance is equipped with
a three pronged (grounding) plug
for your protection against shock
hazard and should be plugged
directly into a properly grounded
three-prong receptacle. Do not
cut or remove the grounding
prong from this plug.
Содержание L234-LP10
Страница 37: ...Liberty L234 10 Direct Vent Gas Insert 37 37 warranty MAIN ASSEMBLY a ...
Страница 38: ...38 Liberty L234 10 Direct Vent Gas Insert 38 parts list 537 924 Low Profile Faceplate ...
Страница 39: ...Liberty L234 10 Direct Vent Gas Insert 39 39 notes ...
Страница 44: ...44 Liberty L234 10 Direct Vent Gas Insert 44 warranty ...
Страница 45: ...Liberty L234 10 Direct Vent Gas Insert 45 45 notes ...
Страница 46: ...46 Liberty L234 10 Direct Vent Gas Insert 46 notes ...
Страница 47: ......