Regency I43-1 ULTIMATE Gas Inbuilt Fireplace
INSTALLATION CHECKLIST
The Regency Gas Inbuilt is installed as listed below.
1)
Unit Location - check Clearances to Combustibles on page
7.
2)
Make the gas connections and electrical connection for
fan and fl ue spill switch. See page 8.
3)
Install
the
fl ue or liner to the sliding draft diverter. See page
9.
4)
Install Flueing, page 9. Slide the unit into the fi replace and
level. Attach draft diverter to the inbuilt.
5)
Test gas pressure, page 10. Check aeration, page 10.
6)
Test
for
fl ue spillage, page 11.
7)
Assemble and install the faceplate and trim. See page 12.
8)
Install the optional brick panels. See page 13.
9)
Install the 3 logs and embers. See page 13.
10)
Install Doors. See page 14.
11)
Install Optional Remote Control and Optional Wall Ther-
mostat, pages 14 and 15.
12)
Explain controls to the homeowner.
13)
Final check:
Before leaving this unit with the customer,
the installer must ensure that the appliance is fi ring cor-
rectly. This includes:
a)
Clocking the appliance to ensure the correct fi ring
rate.
b)
Adjusting the primary air, if required, to ensure that
the fl ame does not carbon. See page 10.
c)
Ensuring that the appliance is fl ueing correctly. See
page 11.
MATERIALS REQUIRED
No electrical power supply is required for the gas control to
operate. A 240 Volt AC power cord is hooked up to the fan
switch and fan. Plug 3 wire cord into a suitable receptacle.
Do
not cut the ground terminal off under any circumstances.
When connected with 240 volts, the appliance must be elec-
trically grounded in accordance with local codes, or in the
absence of local codes with the current version of National
Code AS 3100.
INSTALLATION REQUIREMENTS
Note: This unit is equipped with a heat sensor thermodisc
which will prevent the fan from operating until the
unit reaches the correct temperature.
CLEARANCES
Minimum Fireplace Clearances
The minimum fi replace clearances for the Regency gas inbuilt
fi replace are shown in the following diagrams: