background image

Models: I43-NG1
  

I43-LPG1

Vienns

Owners &
Installation

 

Man

ual

09/12/12

LISTINGS AND CODE APPROVALS

These gas appliances have been tested in 
accordance with AS4553-2000, NZS 5262 
and have been certifi ed by the Australian 
Gas Association for installation and opera-
tion as described in these Installation and 
Operating Instructions.

Your unit should be serviced annually 
by an authorised service person.

908-058b

I43-1 Gas Inbuilt

PLEASE KEEP THESE INSTRUCTIONS 

FOR FUTURE REFERENCE

FOR YOUR SAFETY
What to do if you smell gas:

 

Do not try to light any ap-
pliance

 

Do not touch any electri-
cal switch: do not use any 
phone in your building.

 

Immediately call your gas 
supplier from a neigh-
bour's phone. Follow the 
gas supplier's instruc-
tions.

 

If you  cannot reach your 
gas supplier, call the 

fi

 re 

WARNING:  
Improper installation, adjustment, altera-
tion, service or maintenance can cause 
injury or property damage. Refer to this 
manual. For assistance or additional in-
formation consult an authorised installer, 
service agency or the gas supplier.

FOR YOUR SAFETY
Do not store or use gasoline or other 

fl

 am-

mable vapours and liquids in the vicinity of 
this or any other appliance.
Installation and service must be performed 
by an authorised installer, service agency or 
the gas 

supplier.

Содержание I43-LPG1

Страница 1: ...t any ap pliance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplier from a neigh bour s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the fire WARNING Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to this manual For assistance or addit...

Страница 2: ...s of hand crafted appli ances has been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch The models I43 NG1 and I43 LPG1 of this series have been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment no...

Страница 3: ...tion System 10 Test For Flue Spillage 11 Faceplate Trim Installation 12 Brick Panels 13 Log Installation 13 Door Installation Door Latches 14 Optional Wall Thermostat Installation 14 Optional Remote Control Installation 15 Final Check 15 Wiring Diagram 15 OPERATING INSTRUCTIONS Operating Instructions 16 Lighting Procedure 16 Shutdown Procedure 16 Copy of Lighting Plate Instructions 17 First Fire 1...

Страница 4: ...safety label is located on the right side door panel DATA BADGE NOTE Regency units are constantly being improved Check the label on the unit and if there is a differ ence the label on the unit is the correct one Gas Type NG LPG NG LPG Model Gas Consumption 40 39 33 33 Manifold Pressure 85 2 55 80 2 38 Injector Size 1x 31 1x 56 1x 36 1x 52 I43 NG I43 LPG F33 NG F33 LPG mj mj mj mj kPa kPa kPa kPa E...

Страница 5: ... regulations with AS5601 2004 AGA gas installation code NZS 5261 New Zealand 2 Installation and repair should be done ONLY by an authorised person 3 The appliance should be inspected before use and at least annually by an authorised service person More frequent cleaning may be required due to ex cessive lint from carpeting bedding material etc It isimperativethatcontrolcompartments burnersand circ...

Страница 6: ...ith the customer the installer must ensure that the appliance is firing cor rectly This includes a Clocking the appliance to ensure the correct firing rate b Adjusting the primary air if required to ensure that the flame does not carbon See page 10 c Ensuring that the appliance is flueing correctly See page 11 MATERIALS REQUIRED No electrical power supply is required for the gas control to operate...

Страница 7: ...acing Mantel Leg Side K 1 25 mm Top L 1 25 mm Max width of 25mm at 25mm from surround calculate Top View Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Mantle Clearances mm Width Mx 140 152 165 178 190 203 216 229 241 Clearance My 279 289 298 311 317 321 324 327 330 Non combustible Hearth Extension mm Heig...

Страница 8: ...ction is a 1 2 BSP male pipe on the rear left side of the unit The gas line can be rigid pipe or to make installation easier use a listed flex ible connector and manual shut off valve if allowed by local building codes A 1 2 gas supply pipe must be brought near this inlet hole 3 Locate the center point where the flue will pass through the chimney above the appliance Move the appliance into the exa...

Страница 9: ...d an adequate draft is present when the unit is in operation See page 11 for spill age test Before installing flue system ensure that the damper plate is locked into the open position and secure to prevent the damper plate from falling down and crushing the liner INSTALLATION DRAFT DIVERTER CONNECTION 1 Attach the flue to the flue collar on the detachable draft diverter The flue collar of the appl...

Страница 10: ...e flue by placing a smoke match cigarette or similar device which gives off smoke in front of the spill tube To ensure a valid test place a scrap piece of sheet metal or other non combustible material between the spill tube and the upper louvre this will prevent the natural convection of the unit from interfering with the test See diagrams below The smoke should be drawn into the spill tube if it ...

Страница 11: ...ilt into the gas control and should be checked at the pressure test point normal draft downdraft or blocked flue Spill Tube Non combustible Scrap Note To properly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the valve is in the off position 2 Loosen the screw at the outlet pressure test point turn captured screw coun...

Страница 12: ...led faceplate panels aligning the wires from the switches with the notch in the left side faceplate panel 5 FAN switch wires Hookup the 3 Fan Switch wires to the fan switch on the left side trim 6 BurnerON OFFwires Hookupthe2BurnerON OFFwires to the Burner switch on the left side trim Diagram 3 7 The power cord should be run behind the faceplate panel 8 Push the logo plate into the two holes in th...

Страница 13: ...use the unit until they are replaced Broken logs can interfere with the pilot and burner operation The gas log kit contains the following a Front Right Log Part 902 192 b Front Left Log Part 902 193 c Rear log Part 902 194 d Embers Part 902 151 1 bag Part 650 933 for the set of three logs 1 Remove the logs from the box and carefully unwrap them The logs are fragile handle with care DO NOT FORCE in...

Страница 14: ...ull the paper out If it slips out easily then the door is not properly sealed Turn the adjustable catch to tighten or loosen the latch See diagram 3 Note The door latch may require adjustment as the door gasket material compresses after a few fires and after glass replacement Turn the latch to tighten or loosen the latch Thermostat Wire Table Recom mended Maximum Lead Length Two Wire When Us ing W...

Страница 15: ...l wires to the 240V wires 3 Install alkaline batteries in both the receiver and the trans mitter Install the receiver and its cover in the wall Switch the hand held remote transmitter to remote mode The remote control is now ready for operation FINAL CHECK Beforeleavingthisunitwiththecustomer theinstallermustensure that the appliance is firing correctly This includes 1 Check operating pressure see...

Страница 16: ...ce 5 Wait five minutes to allow gas that may have accumulated in the main burner compartment to escape If you do smell gas follow the instructions on the front of this manual If you don t smell gas continue on to the next step 6 Turn the gas control counterclockwise to PILOT 7 Push in control knob all the way and hold in Immediately pushblackbuttononsparkigniteruntilpilotlights Continue to hold th...

Страница 17: ...after the pilot is lit Releaseknobanditwillpopbackup Pilotshould remain lit If it goes out repeat steps 3 and 4 If knob does not pop up when released stop and immediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 5 Turngascontrolknobcounterclockwise to ON 6 Use ro...

Страница 18: ...he fact that there are various gauges and types of steel used within your ap pliance Listed below are some examples All are normal operating sounds and should not be considered as defects in your appliance Fan Regency gas appliances use high tech fans to push heated air farther into the room It is not unusual for the fan to make a whirring sound when ON This sound will increase or decrease in volu...

Страница 19: ... authorised field service person to ensure that the flow of combustion and ventilation air is not obstructed 5 Keep the area near the appliance clear and free from combustible materials gasoline aerosols and other flam mable vapours and liquids 7 Periodically check the pilot flames Correct flame patflames notcomingintopropercontactwiththerear burner or thermopile or thermocouple tern has three str...

Страница 20: ...LOG REPLACEMENT The unit should never be used with broken logs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs The pilot light generates enough heat to burn someone If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagram under Log Installation NOTE Improper ...

Страница 21: ...e 2 pins tip forward and pull through firebox opening Installing Glass 1 Install both center and side glass onto extrusions as per diagram IMPORTANT These fans do collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis by vacuuming out the fan squirrel cages Replacing fan Reverse above steps Hint for pushing fan down onto pins rub a bit of dish soap on t...

Страница 22: ...oped around thermopile and thermocouple and correct millivolt reading is set Be sure wire connections at gas valve terminals are tight and ther mopile and thermocouple are fully inserted into pilot bracket One of the switch wires may be grounded May be grounded to gas appliance or gas supply Check thermopile with millivolt meter Take reading at thermopile terminals of valve TP TPTH Should read 250...

Страница 23: ... End 910 784 Wire Harness Stove End 19 613 520 Side Panel Door Assy Left 20 650 527 Side Panel Door Hinge Bracket Left 21 613 522 Side Panel Door Assy Right 22 650 528 Side Panel Door Hinge Bracket Right 24 948 241 Door Latch 25 910 325 Spill Switch 27 910 142 Thermodisc Fan Auto On Off 28 Mounting Bracket Fan Switch 29 Thermodisc Cover 30 610 175 Rear Panel 32 710 028 Faceplate Mounting Bracket 6...

Страница 24: ...ly NG 611 566 P Valve Assembly LPG 60 910 028 Valve NG 910 029 Valve LPG 904 690 31 Orifice NG 904 163 54 Orifice Front LPG 904 241 56 Orifice Rear LPG 73 910 048 Pilot Assy S I T 4 flame NG 910 049 Pilot Assy S I T 4 flame LPG 74 650 933 Pkg Log Set 75 902 192 Front Log Right 76 902 193 Front Log Left 77 902 194 Rear Log 902 151 Embers 78 651 578 Burner Assy NG 79 651 575 Burner Assy LPG 91 910 3...

Страница 25: ...witch and Fan Switch 91 Faceplate Side Right Standard 92 Faceplate Top Assy Standard 93 Faceplate Side Left Standard 94 Faceplate Trim Right Standard 95 Faceplate Trim Top Standard 98 Faceplate Trim Left Assy Standard with Burner Switch and Fan Switch 96 910 246 Burner ON OFF Switch 97 910 140 Fan HI OFF LOW Switch 240 V 910 784 Wire Harness Faceplate end 910 782 Wire Harness Fan End 101 Faceplate...

Страница 26: ...d Door Complete Assy 650 974 Black Door Complete Assy 101 650 920 Door Gasket Kit 105 3 4 Ceramic Paper 106 940 226 P Side Glass 107 936 243 Glass Gasket 108 940 227 P Centre Glass 111 Door Frame Gasket Gold door only 112 650 236 Door Glass Aluminium Extrusion 113 Door Frame Gold Plated mitred Door Frame Black mitred ...

Страница 27: ...agent or the closest approved service agent is situated more than thirty 30 kilometres from the installation Regency is not obliged to arrange warranty repairs and travel and or additional labour charges will apply Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim It does not cover installation and operational related problems such as ove...

Страница 28: ...Printed in Canada Copyright 2012 FPI Fireplace Products International Ltd All rights reserved ...

Отзывы: