L540PB-2 / HZI540PB-2 Direct Vent Gas Insert
19
INSTALLATION
GT REMOTE CONTROL INSTALLATION
Note:
GT remote control installation must be completed prior to the unit
being installed.
1.
Bring the TH, TPTH, and Stepper motor wires around back of the unit to
the left side - where the valve is located.
GT Remote Receiver Components
1
946-680
GT remote control
2.
Connect the TH/TP-TH wires from the harness to the valve terminals also
marked TH/TP-TH - locations as shown below.
3.
Secure cable ties to the unit as shown by inserting cable ties into round
holes. There will be a total of 4 cable ties that need to be inserted into the
holes. (2 on the back and 2 on the right side located on the lower side of
the fi rebox).
TPTH Wire
TH Wire
Secure wires with cable ties installed in previous step.
Additionally secure wires with a wire clip to be installed in location show
below.
Cable Tie
Wire Clip
Left
Right
Cable Tie
Cable Tie
4.
Install receiver onto backing plate with 2 screws and plug in receiver
wires.
5.
Bundle excess receiver wire using the 4th cable tie and secure to the
front right of the fi rebox as shown below.