12
|
LRI4E / HRI4E Direct Vent Gas Insert
|
12
installation
A
B
C
MATERIALS REQUIRED
A 120 Volt AC power cord is hooked up to operate the fan and operate the gas valve when batteries are
not installed in the receiver. Plug the 3 wire cord into a suitable receptacle. Do not cut the ground
terminal off under any circumstances. When connected with 120 volts, the appliance must be
electrically grounded in accordance with local codes, current version of CSA C22.1 (in Canada) or in
the absence of local codes, with the National Electrical Code ANSI/NFPA 70-1987.
INSTALLATION
CHECKLIST
Before installing vent system ensure that the damper
plate is open and secure to prevent the damper plate
from falling down and crushing the liner.
The Regency Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer to
sections "Minimum Fireplace Dimensions and
Clearances to Combustibles)
2) Make the gas connection. (Refer to section "Gas
Connection")
3) Install the two 3" flue liners (intake and exhaust)
to the sliding connector plate. (Refer to section
"Flue Liner Installation.")
4) Slide the unit half way into the fireplace.
5) Pull the vent connector plate through the tapered
brackets and fasten to the front plate. Refer to
section "Flue Liner Installation.")
6) Slide the unit fully into the fireplace. Level if
necessary.
7) Hook up 120 volt AC power cord into a suitable
receptacle. Optional: Install 4 batteries in
receiver. Batteries only serve as back up if
power is lost within the home.
8) Test gas pressure (Refer to section "Gas Pipe
Pressure Testing"). Check aeration system
(Refer to section "Gas Insert Aeration System").
9) Install standard and optional features. Refer to
the following sections:
a. Brick Panels or Enamel Panels
(must be installed)
b. Log Set
c. Glass Crystals
d. Spa stones
e Standard Faceplate
f. Low Profile Faceplate
g. 4 sided faceplate.
10) Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is firing correctly. This includes:
a)
Clocking the appliance to ensure the correct
firing rate.
b)
Adjusting the primary air, if required, to
ensure that the flame does not carbon. See
"Gas Insert Aeration System" section.
c)
Ensuring that the appliance is venting
correctly.
MINIMUM FIREPLACE DIMENSIONS
The minimum fireplace clearances & dimensions for the Regency gas insert are shown in the following
diagrams:
Max Lentil Bar
Depth
A
Height
B
Depth
C
Width
(rear)
D
Width
(front)
E
Width
F
Front Depth
To Taper
G
Low
Profile
Faceplate
10"
20"
15.75"
22"
30"
31-1/4"
2-1/8"
Vignette
Faceplate
12.25"
20"
18"
22"
30"
35-5/8"
4-3/8"
Vignette
Faceplate
w/Spacer
10"
20"
15.75"
22"
30"
31-1/4"
2-1/8"
Содержание HRI4E-LP
Страница 5: ...LRI4E HRI4E Direct Vent Gas Insert 5 5 dimensions UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE ...
Страница 6: ...6 LRI4E HRI4E Direct Vent Gas Insert 6 dimensions UNIT DIMENSIONS WITH 4 SIDED VIGNETTE FACEPLATE ...
Страница 51: ...LRI4E HRI4E Direct Vent Gas Insert 51 51 parts list 12 ...
Страница 53: ...LRI4E HRI4E Direct Vent Gas Insert 53 53 notes ...
Страница 54: ...54 LRI4E HRI4E Direct Vent Gas Insert 54 notes ...