LRI4E / HRI4E Direct Vent Gas Insert
|
11
|
11
installation
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The Regency Gas Insert must be installed in
accordance with these instructions. Carefully read
all the instructions in this manual first. Consult the
building authority having jurisdiction to determine
the need for a permit prior to starting the installation.
NOTE: Failure to follow the instructions could cause
a malfunction of the heater which could result in
death, serious bodily injury, and/or property damage.
Failure to follow these instructions may also void
your fire insurance and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion.
Always provide adequate combustion and ventilation
air. Follow instructions and information in CAN/CGA
B149 (in Canada) or the National Fuel Gas Code
ANSI Z223.1 (in the USA), regarding requirements
for combustion and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit must
be disconnected.
Gas Input Capacity:
Natural Gas
31,000
Btu/h
Propane
31,000
Btu/h
Min. Input
(with Proflame GTM or GTMF remote)
Natural Gas
22,000 Btu/h
Propane
26,000 Btu/h
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to 4,500'
(0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 140 CFM.
Log Set: Ceramic fibre, 7 per set - LRI4E
Glass Crystals: 7lbs of glass crystals - HRI4E
Optional Log Set: Ceramic fibre, 6 per set + 5lbs
of glass crystals - HRI4E
Vent System: 3" co-linear aluminum flex.
The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and was
determined independent of any installed system.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual
shut off valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psig. (3.45 kPa).
INSTALLATION INTO A SOLID
FUEL BURNING FIREPLACE
OR FACTORY BUILT
FIREPLACE
The LRI4E / HRI4E Gas Inserts have been tested
and approved to be vented into any masonry
fireplace or approved solid fuel burning factory
built fireplace that will allow the insert to physically
fit into the firebox. Refer to "Minimum Fireplace
Dimensions" section for minimum fireplace
clearances.
If the factory built fireplace* height is too low for
your Insert, you may remove the smoke baffle
plate, damper, refractory (firebricks), glass doors,
screen rails, screen mesh and log grates from the
factory built fireplace as long as these items are
saved and are reinstalled in the event that the
Insert is removed.
Smoke shelves, shields and baffles may be
removed if attached by mechanical fasteners. If any
part is removed it must not weaken the structural
integrity of the factory built fireplace.
NOTE: Any alterations made to the listed solid
fuel burning factory built fireplace may void the
listing of the fireplace.
*Check with your local inspector before
commencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:
General Safety Information
1) The appliance installation must conform with
local codes or in the absence of local codes,
with CAN/CGA B149 (in Canada) or the National
Fuel Gas Code ANSI Z223.1 in the U.S.A. This
appliance should be installed by a qualified gas
fitter technician only.
2) Installation and repair should be done by a
qualified service person.
3) The appliance should be inspected before use
and at least annually by a professional service
person. More frequent cleaning may be required
due to excessive lint from carpeting, bedding
material, animal hair, etc. It is imperative that
control compartments, burners and circulating
air passageways of the appliance be kept clean.
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible fireplace.
5) This appliance is Listed for bedroom installations
when used with a Listed Millivolt Thermostat.
Some areas may have further requirements,
check local codes before installation.
6) Always connect this insert to a vent system
venting to the outside of the building envelope.
Never vent to another room or inside a building.
Make sure that the vent is properly sized and is
of adequate height to provide the proper draft.
7) Inspect the venting system annually for blockage
and any signs of deterioration.
8) Any glass removed for servicing must be
replaced prior to operating the appliance.
9) To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fireplace.
10) This appliance cannot be operated without brick
or enamel panels in place.
11) Due to high temperatures, the appliance should
be located out of high traffic areas and away
from furniture and draperies. Children and
adults should be alerted to the hazards of high
surface temperatures, especially the fireplace
glass and gold trims, and should stay away to
avoid burns or clothing ignition. Young children
should be carefully supervised when they are
in the same room as the appliance. Clothing or
other flammable material should not be placed
on or near the appliance.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects
or other reproductive harm.
Installer must mechanically attach the supplied
label to the inside of the firebox of the fireplace
into which the gas fireplace insert is installed.
" WARNING: This fireplace has been
converted for use with a gas fireplace insert
only and cannot be used for burning wood or
solid fuels unless all original parts have been
replaced, and the fireplace re-approved by the
authority having jurisdiction."
Содержание HRI4E-LP
Страница 5: ...LRI4E HRI4E Direct Vent Gas Insert 5 5 dimensions UNIT DIMENSIONS WITH LOW PROFILE FACEPLATE ...
Страница 6: ...6 LRI4E HRI4E Direct Vent Gas Insert 6 dimensions UNIT DIMENSIONS WITH 4 SIDED VIGNETTE FACEPLATE ...
Страница 51: ...LRI4E HRI4E Direct Vent Gas Insert 51 51 parts list 12 ...
Страница 53: ...LRI4E HRI4E Direct Vent Gas Insert 53 53 notes ...
Страница 54: ...54 LRI4E HRI4E Direct Vent Gas Insert 54 notes ...