![Regency H200 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/regency/h200/h200_owners-and-installation-manual_1433825015.webp)
Hampton® H200 Cast Freestanding Woodstove
|
15
15
|
installation
RECOMMENDED HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1)
At sea level minimum height is 12'
straight.
2)
Add the following vertical height to compen-
sate for:
45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T"
= 3 ft.
Each foot of horizontal run = 2 ft.
3)
Add 4% overall for each 1000' above sea
level.
Example: a)
1-1/2 ft. of horizontal run
= 3 ft.
one "T"
= 3 ft.
Total Addition (at sea level) = 6 ft.
Example: b)
One 90 deg. elbow
= 2 ft.
2 ft. of horizontal run
= 4 ft.
one "T"
= 3 ft.
Total Addition (at sea level) = 9 ft.
Recommended Flue Height
Elevation Example a) Example b)
0' 18'
21'
1000'
18.72'
21.84'
2000'
19.44'
22.68'
5000'
21.60'
25.20'
8000'
23.76'
27.72'
TABLE 1
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
# OF ELBOWS
ELEVATION (FT)
ABOVE SEA LEVEL
0 2 x 15
o
4 x 15
o
2 x 30
o
4 x 30
o
2 x 45
o
4 x 45
o
0-1000
12.0
13.0
14.0
15.0
18.0
16.0
20.0
1000-2000
12.5 13.5 14.5 15.5 19.0 16.5 21.0
2000-3000
13.0 14.0 15.0 16.0 19.5 17.0 21.5
3000-4000
13.5 14.5 15.5 17.0 20.0 18.0 22.5
4000-5000
14.0 15.0 16.0 17.5 21.0 18.5 23.0
5000-6000
14.5 15.5 17.0 18.0 21.5 19.0 24.0
6000-7000
15.0 16.0 17.5 18.5 22.5 20.0 25.0
7000-8000
15.5 16.5 18.0 19.0 23.0 20.5 25.5
8000-9000
16.0 17.0 18.5 20.0 24.0 21.0 26.5
9000-10000
16.5 17.5 19.0 20.5 24.5 22.0 27.0
NOTE: No more than two offsets (four elbows) allowed
.
Two 45
o
elbows equal one 90
o
elbow.
Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney,
local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance and may cause damage. An
uncontrollable burn or excessive temperature indicates excessive draft. Inadequate draft may cause back puffing into the room and plugging of the chimney.
Inadequate draft will cause the appliance to leak smoke into the room through appliance and chimney connector joints. Ensure the heater is installed in areas
that are not too close to neighbors or in valleys that would cause unhealthy air quality or nuisance conditions.