![Regency H200 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/regency/h200/h200_owners-and-installation-manual_1433825010.webp)
10
|
Hampton® H200 Cast Freestanding Woodstove
|
10
installation
MINIMUM ALCOVE CLEARANCE TO
COMBUSTIBLE MATERIALS
This Hampton Freestanding model has been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height (from finished floor) - 60" (1525 mm)
Maximum depth of alcove - 48" (1219 mm)
NOTE: This clearance is also required for air space between the appliance and wall/ceiling.
From
From Flue Min. Min.Hearth
Unit (with Heat Shield)
Unit
Center-line Width to Rear Wall
G H
I J K L
H200
15" (381 mm) 13" (330 mm) 27" (686 mm) 15-1/8" (384 mm) 54" (1372 mm) 50" (1270 mm)
ADDITIONAL CLEARANCES
FOR BACKWALL EXIT
From
Unit (with Heat Shield)
Unit
A B
H200
9" (228 mm) 15" (381 mm)
Note: Floor Protection must extend 2" (51mm)
to each side of the elbow.
Minimum Clearance to Combustibles
Minimum Clearance to Non-Combustibles
From
Unit (with Heat Shield)
Unit
A B
H200
min. 0" (0 mm) 15" (381 mm)
max. 9" (228 mm)
Min. Mantel Height (from finished floor):
48" (1219 mm)
Max. Mantel Depth:
12" (305 mm)
Содержание H200
Страница 35: ...Hampton H200 Cast Freestanding Woodstove 35 35 notes ...
Страница 40: ......
Страница 41: ...Hampton H200 Cast Freestanding Woodstove 41 41 notes ...
Страница 42: ...42 Hampton H200 Cast Freestanding Woodstove 42 notes ...
Страница 43: ......